MedElevator Войти в исследования
← Поиск публикаций

DOI 10.64898/2026.09.14.751507

Медицинская библиотека · bioRxiv : the preprint server for biology · 2026

A custom two-in-one HIST and line-scanning confocal excitation module.

Arthur Christian, Milkie Daniel E, Ulmer Andrew J, Ellis Justin P, Kim Hark Kyun, Song Feifei, Chavez Alejandro, Legant Wesley R

СтатьяПрепринтПеревод в очереди

Аннотация

Fluorescence microscopy applications often require specialized instruments that are optimized for different experimental goals. Here, we present a reconfigurable microscopy module that integrates highly inclined swept tile (HIST) illumination for high-sensitivity single-molecule imaging and line-scanning confocal microscopy for rapid and optically sectioned volumetric acquisition. The system shares major hardware components, including lasers, scanning optics, and detection hardware, while employing unique beam shaping pathways to enable rapid switching between modalities without realignment. We characterize the module performance by measuring the excitation beam profiles, the point spread functions (PSF), and the optical transfer functions (OTF) across 40x, 60x, and 100x magnifications and demonstrate imaging applications including diffraction-limited fixed and live-cell volumetric imaging, fluorescence recovery after photobleaching, and super-resolution DNA-PAINT and single particle tracking (SPT). We also demonstrate the capability to execute multimodal imaging workflows by performing confocal imaging for chromatin density classification correlated with SPT data of nuclear proteins with diverse functions. Together, these results demonstrate a versatile imaging platform capable of supporting complementary fluorescence imaging modalities within a single instrument.

Для цитирования: Arthur Christian, Milkie Daniel E, Ulmer Andrew J, Ellis Justin P, Kim Hark Kyun, Song Feifei, Chavez Alejandro, Legant Wesley R. A custom two-in-one HIST and line-scanning confocal excitation module.. bioRxiv : the preprint server for biology. 2026. DOI: 10.64898/2026.09.14.751507.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.