Philadelphia Telemedicine Glaucoma Detection and Follow-up Study: Methods and Screening Results.
Аннотация
PURPOSE: To describe methodology and screening results from the Philadelphia Telemedicine Glaucoma Detection and Follow-up Study.
DESIGN
Screening program results for a prospective randomized clinical trial.
METHODS
Individuals were recruited who were African-American, Hispanic/Latino, or Asian over age 40 years; white individuals over age 65 years; and any ethnicity over age 40 years with a family history of glaucoma or diabetes. Primary care offices and Federally Qualified Health Centers were used for telemedicine (Visit 1). Two posterior fundus photographs and 1 anterior segment photograph were captured per eye in each participant, using a nonmydriatic, autofocus, hand-held fundus camera (Volk Optical, Mentor, Ohio, USA). Medical and ocular history, family history of glaucoma, visual acuity, and intraocular pressure measurements using the ICare rebound tonometer (ICare, Helsinki, Finland) were obtained. Images were read remotely by a trained retina reader and a glaucoma specialist.
RESULTS
From April 1, 2015, to February 6, 2017, 906 individuals consented and attended Visit 1. Of these, 553 participants were female (61.0%) and 550 were African-American (60.7%), with a mean age of 58.7 years. A total of 532 (58.7%) participants had diabetes, and 616 (68%) had a history of hypertension. During Visit 1, 356 (39.3%) participants were graded with a normal image. Using image data from the worse eye, 333 (36.8%) were abnormal and 155 (17.1%) were unreadable. A total of 258 (28.5%) had a suspicious nerve, 62 (6.8%) had ocular hypertension, 102 (11.3%) had diabetic retinopathy, and 68 (7.5%) had other retinal abnormalities.
CONCLUSION
An integrated telemedicine screening intervention in primary care offices and Federally Qualified Health Centers detected high rate of suspicious optic nerves, ocular hypertension, and retinal pathology.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.