MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/14756366.2018.1445737

Медицинская библиотека · Journal of enzyme inhibition and medicinal chemistry · 2018

Resolution of co-eluting isomers of anti-inflammatory drugs conjugated to carbonic anhydrase inhibitors from plasma in liquid chromatography by energy-resolved tandem mass spectrometry.

Menicatti Marta, Pallecchi Marco, Bua Silvia, Vullo Daniela, Di Cesare Mannelli Lorenzo, Ghelardini Carla, Carta Fabrizio, Supuran Claudiu T, Bartolucci Gianluca

СтатьяПеревод в очереди

Аннотация

Rheumatoid arthritis (RA) is a chronic inflammatory disease caused by a faulty autoimmune response. Recently, it was reported that some human carbonic anhydrases (CAs) isoforms are overexpressed in inflamed synovium of RA patients. New CA inhibitors (CAIs) incorporating CA-binding moiety and the cyclooxygenase inhibitor tail (nonsteroidal anti-inflammatory drug [NSAID] type) were studied. The aim of this work is the evaluation of the chemical stability of NSAID - CAI hybrids towards spontaneous or enzymatic hydrolysis by LC-MS/MS. The analytes are isomer pairs of 6- or 7-hydroxycoumarin, their different fragment ions abundances allowed the development of a mathematical tool (LEDA) to distinguish them. LEDA reliability at ng mL-1 level was checked (>90%), being proved the effectiveness in the correct assignment of the isomer present in the sample. The hybrids resulted stable in all tested matrices allowing us to conclude that these compounds reach the target tissues unmodified, opening perspectives for their development in the treatment of inflammation.

Для цитирования: Menicatti Marta, Pallecchi Marco, Bua Silvia, Vullo Daniela, Di Cesare Mannelli Lorenzo, Ghelardini Carla, Carta Fabrizio, Supuran Claudiu T, Bartolucci Gianluca. Resolution of co-eluting isomers of anti-inflammatory drugs conjugated to carbonic anhydrase inhibitors from plasma in liquid chromatography by energy-resolved tandem mass spectrometry.. Journal of enzyme inhibition and medicinal chemistry. 2018. DOI: 10.1080/14756366.2018.1445737.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.