Comparison of Efficacy and Complications of Cyclophotocoagulation and Second Glaucoma Drainage Device After Initial Glaucoma Drainage Device Failure.

Wang Margaret Y, Patel Kishan, Blieden Lauren S, Chuang Alice Z, Baker Laura A, Bell Nicholas P, Feldman Robert M

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

PURPOSE: Compare intraocular pressure (IOP) control and complication rates of a second glaucoma drainage device (GDD) to diode transscleral cyclophotocoagulation (TSCPC) following failure of an initial GDD.

PATIENTS AND

METHODS

Eyes with 1 GDD that required a second GDD or TSCPC for glaucoma control were included. Exclusion criteria were a cyclodestructive procedure before initial GDD, no light perception vision, or follow-up <1 year. Failure was defined as ≥1 of (1) reoperation for lowering IOP; (2) explantation of second GDD; (3) persistent hypotony; (4) use of oral carbonic anhydrase inhibitor for lowering IOP in the study eye; or (5) loss of light perception. Reoperation for lowering IOP included additional GDD implantation or additional cyclodestruction, except if additional cyclodestruction was within 6 months of the initial session.

RESULTS

A total of 75 eyes (35 in second GDD; 40 in TSCPC) were included (mean follow-up, 25.5 mo). Both procedures lowered IOP [-11.4 mm Hg (±13.6) for second GDD and -7.8 mm Hg (±11.8) for TSCPC groups] and decreased the number of IOP-lowering medications at the last visit. The second GDD group had significantly greater mean survival time [45.0 mo (±4.2)] than the TSCPC group [26.5 mo (±2.8)] but significantly more postoperative complications (60% of eyes) and non-IOP-related procedures (40% of eyes) than the TSCPC group (20% for postoperative complications and 18% for non-IOP-related procedures).

CONCLUSIONS

Although both second procedures are efficacious in lowering IOP and number of IOP-lowering medications, TSCPC failed earlier, whereas a second GDD had significantly more complications.

Для цитирования: Wang Margaret Y, Patel Kishan, Blieden Lauren S, Chuang Alice Z, Baker Laura A, Bell Nicholas P, Feldman Robert M. Comparison of Efficacy and Complications of Cyclophotocoagulation and Second Glaucoma Drainage Device After Initial Glaucoma Drainage Device Failure.. Journal of glaucoma. 2017. DOI: 10.1097/ijg.0000000000000766.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.