Journal of pharmaceutical and biomedical analysis · 2009
A validated stability-indicating LC method for acetazolamide in the presence of degradation products and its process-related impurities.
СтатьяВалидационное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Srinivasu Prabha, Subbarao Devarakonda V, Vegesna Raju V K, Sudhakar Babu K
Аннотация
The objective of the current study was to develop a validated, specific and stability-indicating reverse phase liquid chromatographic method for the quantitative determination of acetazolamide and its related substances. The determination was done for an active pharmaceutical ingredient, its pharmaceutical dosage form in the presence of degradation products, and its process-related impurities. The drug was subjected to stress conditions of hydrolysis (acid and base), oxidation, photolysis and thermal degradation as per International Conference on Harmonization (ICH) prescribed stress conditions to show the stability-indicating power of the method. Significant degradation was observed during acid and base hydrolysis, and the major degradant was identified by LC-MS, FTIR and (1)H/(13)C NMR spectral analysis. The chromatographic conditions were optimized using an impurity-spiked solution and the generated samples were used for forced degradation studies. In the developed HPLC method, the resolution between acetazolamide and, its process-related impurities (namely imp-1, imp-2, imp-3, imp-4 and its degradation products) was found to be greater than 2. The chromatographic separation was achieved on a C18, 250mmx4.6mm, 5microm column. The LC method employed a linear gradient elution, and the detection wavelength was set at 254nm. The stress samples were assayed against a qualified reference standard and the mass balance was found to be close to 99.6%. The developed RP-LC method was validated with respect to linearity, accuracy, precision and robustness.
Предметные рубрики MeSH
AcetazolamideBuffersCarbonic Anhydrase InhibitorsChromatography, High Pressure LiquidChromatography, Reverse-PhaseDrug ContaminationDrug StabilityGuidelines as TopicHydrogen-Ion ConcentrationHydrolysisMagnetic Resonance SpectroscopyMass SpectrometryOxidation-ReductionPhotolysisReference StandardsReproducibility of ResultsSpectroscopy, Fourier Transform InfraredTechnology, PharmaceuticalTemperature