m+Medelevator.RU
← Поиск публикаций
Ophthalmology · 2008

Intraocular pressure-lowering efficacy of brinzolamide 1%/timolol 0.5% fixed combination compared with brinzolamide 1% and timolol 0.5%.

СтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kaback Martin, Scoper Stephen V, Arzeno George, James John E, Hua Steven Y, Salem Craig, Dickerson Jaime E, Landry Theresa A, Bergamini Michael V W, Brinzolamide 1%/Timolol 0.5% Study Group

Аннотация

PURPOSE: To compare the safety and intraocular pressure (IOP)-lowering efficacy of brinzolamide 1%/timolol 0.5% fixed combination with brinzolamide 1% or timolol 0.5% alone in patients with open-angle glaucoma (OAG) or ocular hypertension (OHT).

DESIGN: Randomized, double-masked, parallel group, multicenter study.

PARTICIPANTS: Five hundred twenty-three patients were randomized to the study treatments.

METHODS: Patients with OAG or OHT were recruited to the study. Qualifying eyes had IOPs of 24 to 36 mmHg at 8 am and 21 to 36 mmHg at 10 am on 2 eligibility visits after an appropriate washout period from previous treatment. Patients were assigned randomly to either brinzolamide 1%/timolol 0.5%, brinzolamide 1% (Azopt; Alcon Laboratories, Fort Worth, TX), or timolol 0.5%, dosed twice daily and were followed up while receiving therapy for 6 months. At selected sites, additional IOP measurements were performed at 12 pm, 4 pm, and 8 pm during the 2 eligibility visits, at month 3, and at month 6.

MAIN OUTCOME MEASURE: Mean IOP.

RESULTS: Brinzolamide 1%/timolol 0.5% produced statistically significant and clinically relevant reductions from baseline ranging from 8.0 to 8.7 mmHg, which were statistically and clinically superior to that of either brinzolamide 1% (5.1-5.6 mmHg) or timolol 0.5% (5.7-6.9 mmHg). No safety concerns were identified based on an assessment of ocular and cardiovascular parameters and a review of adverse events.

CONCLUSIONS: Brinzolamide 1%/timolol 05% is superior in IOP-lowering efficacy to either brinzolamide 1% or timolol 0.5%.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты