PCA3 molecular urine test as a predictor of repeat prostate biopsy outcome in men with previous negative biopsies: a prospective multicenter clinical study.

Gittelman Marc C, Hertzman Bernard, Bailen James, Williams Thomas, Koziol Isaac, Henderson Ralph Jonathan, Efros Mitchell, Bidair Mohamed, Ward John F

СтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: We evaluated the clinical usefulness of the PROGENSA® PCA3 Assay for predicting repeat prostate biopsy outcome.

MATERIALS AND

METHODS

Men with at least 1 prior negative prostate biopsy who were scheduled for repeat prostate biopsy based on best clinical judgment were enrolled at 14 centers. Whole blood and post-digital rectal examination urine samples were collected before extended template transrectal biopsy with 12 or more cores. Urinary PCA3 scores and biopsy outcomes were assessed by logistic regression analysis, which also included age, race, serum prostate specific antigen, clinical stage, family history of prostate cancer and the number of previous negative biopsy sessions.

RESULTS

A total of 466 men were included in study and prostate cancer was identified in 21.9%. A PCA3 score cutoff of 25 yielded 77.5% sensitivity, 57.1% specificity, and negative and positive predictive values of 90% and 33.6%, respectively. On multivariable logistic regression men with a PCA3 score of less than 25 were 4.56 times as likely to have a negative repeat biopsy as men with a score of 25 or greater. PCA3 score significantly increased the predictive accuracy of the logistic regression model. At 90% sensitivity adding the PCA3 score to the model increased specificity, and positive and negative predictive values by 22.6%, 6.4% and 7.1%, respectively, relative to the model without the PCA3 score.

CONCLUSIONS

The PCA3 score supplements serum prostate specific antigen and other clinical information to provide more accurate prediction of repeat biopsy outcome. Thus, it provides clinicians and patients with independent, clinically useful information to make more informed repeat biopsy decisions.

Для цитирования: Gittelman Marc C, Hertzman Bernard, Bailen James, Williams Thomas, Koziol Isaac, Henderson Ralph Jonathan, Efros Mitchell, Bidair Mohamed, Ward John F. PCA3 molecular urine test as a predictor of repeat prostate biopsy outcome in men with previous negative biopsies: a prospective multicenter clinical study.. The Journal of urology. 2013. DOI: 10.1016/j.juro.2013.02.018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.