MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1017/s147895152300086x

Медицинская библиотека · Palliative & supportive care · 2024

Reliability of urine drug testing among patients on buprenorphine transdermal patch.

Amaram-Davila Jaya, Reddy Akhila, Clark Matthew D, Nancherla Anita, Arthur Joseph, Bruera Eduardo

СтатьяКлинический случайПеревод в очереди

Аннотация

BACKGROUND

Urine drug testing (UDT) plays a significant role in monitoring patients on chronic opioid therapy (COT) for non-medical opioid use (NMOU). UDT, at times, can be inconsistent and misleading. We present a case where a patient on a buprenorphine patch had false negative results.

CASE DESCRIPTION: A female in her 70s with metastatic breast cancer presented with uncontrolled pain from a T6 compression fracture. She had no relief with tramadol 50 mg every 6 hours as needed. Due to an allergic reaction to hydromorphone, our team prescribed a buprenorphine patch of 5 μg/h. Subsequently, she expressed excellent pain control, and the clinician confirmed the patch placement on examination. She underwent a UDT during the visit. The UDT was negative for both buprenorphine and its metabolites. The literature review showed that false negative UDT results are relatively common among patients with low-dose buprenorphine patches. The combination of a thorough physical examination, a review of the Prescription Drug Monitoring Program, and reassuring scores on screening tools placed her at low risk for NMOU.

DISCUSSION: Buprenorphine has a ceiling effect on respiratory depression and a lower risk for addiction. However, when used in low doses, the drug might not have enough metabolites in the urine, leading to a false negative UDT. Such results might affect patient-physician relationships.

CONCLUSION

In addition to the UDT, a thorough history, screening for NMOU, physical exam, a review of PDMP, and a good understanding of opioid metabolism are necessary to help guide pain management.

Для цитирования: Amaram-Davila Jaya, Reddy Akhila, Clark Matthew D, Nancherla Anita, Arthur Joseph, Bruera Eduardo. Reliability of urine drug testing among patients on buprenorphine transdermal patch.. Palliative & supportive care. 2024. DOI: 10.1017/s147895152300086x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.