MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3349/ymj.2015.56.5.1352

Медицинская библиотека · Yonsei medical journal · 2015

Screening Ultrasound in Women with Negative Mammography: Outcome Analysis.

Hwang Ji-Young, Han Boo-Kyung, Ko Eun Young, Shin Jung Hee, Hahn Soo Yeon, Nam Mee Young

СтатьяПеревод в очереди

Аннотация

PURPOSE: To show the results of an audit of screening breast ultrasound (US) in women with negative mammography in a single institution and to analyze US-detected cancers within a year and interval cancers.

MATERIALS AND

METHODS

During the year of 2006, 1974 women with negative mammography were screened with US in our screening center, and 1727 among them had pathologic results or any follow up breast examinations more than a year. We analyzed the distribution of Breast Imaging Reporting and Data System (BI-RADS) category and the performance outcome through follow up.

RESULTS

Among 1727 women (age, 30-76 years, median 49.5 years), 1349 women (78.1%) showed dense breasts on mammography, 762 (44.1%) had previous breast US, and 25 women (1.4%) had a personal history of breast cancers. Test negatives were 94.2% (1.627/1727) [BI-RADS category 1 in 885 (51.2%), 2 in 742 (43.0%)]. The recall rate (=BI-RADS category 3, 4, 5) was 5.8%. Eight cancers were additionally detected with US (yield, 4.6 per 1000). The sensitivity, specificity, and positive predictive value (PPV1, PPV2) were 88.9%, 94.6%, 8.0%, and 28.0%, respectively. Eight of nine true positive cancers were stage I or in-situ cancers. One interval cancer was stage I cancer from BI-RADS category 2.

CONCLUSION

Screening US detected 4.6 additional cancers among 1000. The recall rate was 5.8%, which is in lower bound of acceptable range of mammography (5-12%), according to American College of Radiology standard.

Для цитирования: Hwang Ji-Young, Han Boo-Kyung, Ko Eun Young, Shin Jung Hee, Hahn Soo Yeon, Nam Mee Young. Screening Ultrasound in Women with Negative Mammography: Outcome Analysis.. Yonsei medical journal. 2015. DOI: 10.3349/ymj.2015.56.5.1352.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.