PPV(3) of suspicious breast MRI findings.

Smith Haydan, Chetlen Alison L, Schetter Susann, Mack Julie, Watts Meredith, Zhu Junjia Jay

СтатьяПеревод в очереди

Аннотация

RATIONALE AND

OBJECTIVES

Magnetic resonance imaging (MRI) characteristics of Breast Imaging Reporting and Data System (BI-RADS) 4 and 5 lesions were evaluated to identify characteristics that may improve the positive predictive value (PPV) of a biopsy.

MATERIALS AND

METHODS

MRI BI-RADS 4 or 5 breast findings in 101 women who underwent biopsy leading to a diagnosis of cancer within 1 year (PPV3; n = 115 cases) were reviewed. Patient history, lesion morphology, enhancement pattern and kinetics, and T2 characteristics were examined.

RESULTS

The PPV3 of all BI-RADS 4 and 5 breast lesions seen on MRI was 22.6% (26 of 115). Excluding lesions with second-look imaging correlates decreased the PPV3 to 11.8% (6/51). Of the MRI-guided biopsies, 20.9% (24 of 115) yielded a high-risk lesion, altering surgical management. MRI lesion type did not significantly affect the PPV3: the PPV3 was 26.3% (15 of 57) for masses, 21.4% (9 of 42) for non mass enhancement (NME) and 12.5% (2 of 16) for suspicious foci. The PPV3 for lesions found on diagnostic MRI in women with newly diagnosed cancer was 30.8% (20 of 65) which was statistically significantly greater compared to a PPV3 of 11.9% (5 of 42) for lesions identified on high-risk screening MRI.

CONCLUSIONS

Suspicious MRI findings identified on a second-look examination are more likely malignant than those seen only on MRI. Suspicious MRI findings discovered in patients with concurrent malignancy have a greater PPV3 than those detected on high-risk screening MRIs. However, the type of MRI finding (mass vs. NME vs. foci) does not significantly affect the PPV3 and should not be used as a discriminator for determining biopsy threshold.

Для цитирования: Smith Haydan, Chetlen Alison L, Schetter Susann, Mack Julie, Watts Meredith, Zhu Junjia Jay. PPV(3) of suspicious breast MRI findings.. Academic radiology. 2014. DOI: 10.1016/j.acra.2014.07.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.