MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3389/fbioe.2026.1892144

Медицинская библиотека · Frontiers in bioengineering and biotechnology · 2026

Non-Newtonian blood rheology significantly alters hemodynamic predictions during cardiac looping: a computational study.

Watson Matthew C, Kemmerling Erica C, Black Lauren D

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

Hemodynamic forces play a key role in early cardiac morphogenesis, yet many computational studies assume Newtonian blood behavior. Here, we evaluate the impact of non-Newtonian shear-thinning rheology on flow patterns, pressure distributions, and wall shear stress (WSS) during cardiac looping using idealized three-dimensional models of the embryonic heart tube.

METHODS

Five geometries representing progressive looping stages, from a linear tube to an S-shaped configuration with ventricular ballooning, were analyzed under pulsatile flow using both Newtonian and power-law viscosity models.

RESULTS AND DISCUSSION: Across all stages, Reynolds numbers (Re ≈ 1-7) and Womersley numbers (Wo ≈ 0.3) indicated laminar, quasi-steady flow consistent with embryonic conditions. Incorporating shear-thinning rheology produced substantial deviations from Newtonian predictions, with peak systolic WSS differing by up to ∼94% (range 64%-94% depending on stage) and pressure drops by up to ∼70% (range 48%-70% depending on stage). These effects were most pronounced in regions of increased curvature and geometric complexity. These findings demonstrate that non-Newtonian rheology can substantially alter predicted hemodynamic quantities during cardiac looping and should therefore be considered in future developmental hemodynamic models, particularly when wall shear stress and pressure magnitudes are used to infer mechanobiological responses.

Для цитирования: Watson Matthew C, Kemmerling Erica C, Black Lauren D. Non-Newtonian blood rheology significantly alters hemodynamic predictions during cardiac looping: a computational study.. Frontiers in bioengineering and biotechnology. 2026. DOI: 10.3389/fbioe.2026.1892144.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.