MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1158/1055-9965.epi-12-1117

Медицинская библиотека · Cancer epidemiology, biomarkers & prevention : a publication of the American Association for Cancer Research, cosponsored by the American Society of Preventive Oncology · 2013

Serum factors and clinical characteristics associated with serum E-screen activity.

Wang Jue, Trentham-Dietz Amy, Hemming Jocelyn D C, Hedman Curtis J, Sprague Brian L

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПоддержка правительства СШАПеревод в очереди

Аннотация

BACKGROUND

The E-Screen bioassay can measure the mitogenicity of human serum and thus may be useful as a biomarker in epidemiologic studies of breast cancer. While the assay's MCF-7 cells are known to proliferate in response to estrogen, the specific determinants of variation in E-Screen activity in human serum samples are poorly understood. We sought to identify serum molecules and patient characteristics associated with serum E-Screen activity among postmenopausal women.

METHODS

Postmenopausal women (N = 219) aged 55 to 70 years with no history of postmenopausal hormone use or breast cancer completed a questionnaire and provided a blood sample. Serum was analyzed for E-Screen activity and a variety of molecules including sex hormones, growth factors, and environmental chemicals. Stepwise selection procedures were used to identify correlates of E-Screen activity.

RESULTS

Serum samples from all women had detectable E-Screen activity, with a median estradiol equivalents value of 0.027 ng/mL and interquartile range of 0.018-0.036 ng/mL. In the final multivariable-adjusted model, serum E-Screen activity was positively associated with serum estradiol, estrone, insulin-like growth factor-binding protein (IGFBP)-3, and testosterone levels (all P < 0.05), as well as body mass index (P = 0.03). Serum E-Screen activity was lower among women with higher SHBG (P < 0.0001) and progesterone levels (P = 0.03).

CONCLUSION

Serum E-Screen activity varies according to levels of endogenous estrogens and other serum molecules. Obesity appears to confer additional serum mitogenicity beyond its impact on the measured hormones and growth factors.

IMPACT: By capturing mitogenicity due to a variety of patient and serum factors, the E-Screen may provide advantages for use as a biomarker in breast cancer studies.

Для цитирования: Wang Jue, Trentham-Dietz Amy, Hemming Jocelyn D C, Hedman Curtis J, Sprague Brian L. Serum factors and clinical characteristics associated with serum E-screen activity.. Cancer epidemiology, biomarkers & prevention : a publication of the American Association for Cancer Research, cosponsored by the American Society of Preventive Oncology. 2013. DOI: 10.1158/1055-9965.epi-12-1117.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.