MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · PDA journal of pharmaceutical science and technology · 2009

Reverse-phase, high performance liquid chromatographic method for the determination of tolterodine tartrate in routine quality control samples.

Dwibhashyam V S N Murthy, Keerthi P, Ratna J Vijaya, Nagappa A N

СтатьяПеревод в очереди

Аннотация

A selective, sensitive, and rugged reverse phase-high performance liquid chromatographic method has been developed for the determination of tolterodine tartrate in routine quality control samples. The mobile phase consisted of acetonitrile:phosphate buffer (pH 7.0) in 55:45 v/v ratio. The mobile phase was also used for the extraction of tolterodine tartrate from its formulations. The chromatography was carried out on a Luna 100A, C-18 (5-micro, 250 x 4.60 mm) column. The software used in the chromatographic analysis was Empower Photodiode Array (PDA) software (Waters, Milford, CT). The UV spectrophotometric determination was done at 210 nm. Retention time was found to be about 7.0 +/- 0.5 min. The standard curve was linear (r2 = 0.9997) over the concentration range of 0.1-0.3 mg/mL. The method was found to be accurate, precise, specific, and rugged. The limit of detection was 0.16 microg/mL and the limit of quantification was 0.489 microg/mL. With a short chromatographic run time, the proposed method can be used for the estimation of large number of quality control samples in a short period.

Для цитирования: Dwibhashyam V S N Murthy, Keerthi P, Ratna J Vijaya, Nagappa A N. Reverse-phase, high performance liquid chromatographic method for the determination of tolterodine tartrate in routine quality control samples.. PDA journal of pharmaceutical science and technology. 2009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.