Johnson Latrice A, Harmon Stephanie A, Yilmaz Enis C, Lin Yue, Belue Mason J, Merriman Katie M, Lay Nathan S, Sanford Thomas H, Sarma Karthik V, Arnold Corey W, Xu Ziyue, Roth Holger R, Yang Dong, Tetreault Jesse, Xu Daguang, Patel Krishnan R, Gurram Sandeep, Wood Bradford J, Citrin Deborah E, Pinto Peter A, Choyke Peter L, Turkbey Baris

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

Automated methods for prostate segmentation on MRI are typically developed under ideal scanning and anatomical conditions. This study evaluates three different prostate segmentation AI algorithms in a challenging population of patients with prior treatments, variable anatomic characteristics, complex clinical history, or atypical MRI acquisition parameters.

MATERIALS AND

METHODS

A single institution retrospective database was queried for the following conditions at prostate MRI: prior prostate-specific oncologic treatment, transurethral resection of the prostate (TURP), abdominal perineal resection (APR), hip prosthesis (HP), diversity of prostate volumes (large ≥ 150 cc, small ≤ 25 cc), whole gland tumor burden, magnet strength, noted poor quality, and various scanners (outside/vendors). Final inclusion criteria required availability of axial T2-weighted (T2W) sequence and corresponding prostate organ segmentation from an expert radiologist. Three previously developed algorithms were evaluated: (1) deep learning (DL)-based model, (2) commercially available shape-based model, and (3) federated DL-based model. Dice Similarity Coefficient (DSC) was calculated compared to expert. DSC by model and scan factors were evaluated with Wilcox signed-rank test and linear mixed effects (LMER) model.

RESULTS

683 scans (651 patients) met inclusion criteria (mean prostate volume 60.1 cc [9.05-329 cc]). Overall DSC scores for models 1, 2, and 3 were 0.916 (0.707-0.971), 0.873 (0-0.997), and 0.894 (0.025-0.961), respectively, with DL-based models demonstrating significantly higher performance (p < 0.01). In sub-group analysis by factors, Model 1 outperformed Model 2 (all p < 0.05) and Model 3 (all p < 0.001). Performance of all models was negatively impacted by prostate volume and poor signal quality (p < 0.01). Shape-based factors influenced DL models (p < 0.001) while signal factors influenced all (p < 0.001).

CONCLUSION

Factors affecting anatomical and signal conditions of the prostate gland can adversely impact both DL and non-deep learning-based segmentation models.

Для цитирования: Johnson Latrice A, Harmon Stephanie A, Yilmaz Enis C, Lin Yue, Belue Mason J, Merriman Katie M, Lay Nathan S, Sanford Thomas H, Sarma Karthik V, Arnold Corey W, Xu Ziyue, Roth Holger R, Yang Dong, Tetreault Jesse, Xu Daguang, Patel Krishnan R, Gurram Sandeep, Wood Bradford J, Citrin Deborah E, Pinto Peter A, Choyke Peter L, Turkbey Baris. Automated prostate gland segmentation in challenging clinical cases: comparison of three artificial intelligence methods.. Abdominal radiology (New York). 2024. DOI: 10.1007/s00261-024-04242-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.