Enantiomeric purity methods for three pharmaceutical compounds by electrokinetic capillary chromatography utilizing highly sulfated-gamma-cyclodextrin as the chiral selector.

Ramstad Tore

СтатьяВалидационное исследованиеПеревод в очереди

Аннотация

Methods for enantiomeric purity by electrokinetic chromatography were developed and validated for three pharmaceutical compounds, each utilizing highly sulfated-gamma-cyclodextrin (HS-gamma-CD) as the chiral recognition agent. Two of the compounds are weak bases, hence charged at low pH, and the third is a quaternary nitrogen compound, charged at all pH. In each instance quantification was via an authentic reference standard with addition of an internal standard. Separation was on a 61 cm x 50 microm untreated capillary under reverse polarity with a background electrolyte of 5% HS-gamma-CD in pH 2.50 lithium phosphate buffer. Each method was validated with respect to the usual validation parameters, notably recovery and precision, yielding results, including limits of detection and quantitation, that allow reporting the minor enantiomer to 0.1% and less. In applying the methods, all batches of bulk drug tested were shown to be of enantiomeric purity > or =99.9%.

Для цитирования: Ramstad Tore. Enantiomeric purity methods for three pharmaceutical compounds by electrokinetic capillary chromatography utilizing highly sulfated-gamma-cyclodextrin as the chiral selector.. Journal of chromatography. A. 2006. DOI: 10.1016/j.chroma.2006.06.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.