m+Medelevator.RU
← Поиск публикаций
International urology and nephrology · 2006

The effect of prior biopsy scheme on prostate cancer detection for repeat biopsy population: results of the 14-core prostate biopsy technique.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Eskicorapci Saadettin Yilmaz, Guliyev Fuad, Islamoglu Ekrem, Ergen Ali, Ozen Haluk

Аннотация

OBJECTIVES: To evaluate the diagnostic performance of 14-core repeat biopsy protocol and the impact of prior biopsy scheme on repeat prostate biopsy group.

METHODS: 211 patients had repeat biopsy using 14-core protocol consisting of 10-core peripheral zone (classical sextant+4 lateral peripheral cores) and 4-core transitional zone (TZ) biopsies. The diagnostic yield was determined both in patients who had previously undergone sextant or 10-core biopsy protocol.

RESULTS: Overall cancer detection rate was 25.6%. 14-core biopsy technique detected cancer in 36.1 and 18.7% of the patients who had a previous sextant biopsy and 10-core biopsy protocol, respectively (P = 0.005). Patients with and without high-grade prostatic intraepithelial neoplasia (HGPIN) in the previous sextant biopsy had 56.5 and 28.3% cancer detection rates on the subsequent extended biopsy, respectively (P = 0.017) Patients who had previous 10-core biopsy with and without HGPIN revealed 22.9 and 17.2% cancer detection rates, respectively (P = 0.465) Additional four lateral peripheral cores detected 33% (3/30) and 17% (4/24) of cancers in patients with previous sextant and 10-core biopsy, respectively. 3.7% of the patients had tumor only in the TZ and none of them had prior extended biopsy.

CONCLUSIONS: The yield of extended 14-core repeat biopsy protocol was higher in patients with previous negative sextant biopsy compared to the patients with previous negative 10-core biopsy. HGPIN history found on previous sextant biopsy was a strong cancer predictor on repeat biopsy; same was not true for the patients with previous 10-core biopsy. The yield of lateral peripheral cores and TZ biopsies were lower in patients with prior negative extended biopsy.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты