MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/advs.202515865

Медицинская библиотека · Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025

AIEgen-Based Proactive Early Warning System and Precise Treatment Strategy for Monkeypox Prevention and Control.

Wang Wei, Liu Zining, Li Mengjun, Zheng Judun, Zhang Ruilin, Liu Ke, Li Xiaoxue, Wen Shaoying, Yu Jingze, Pan Meijia, Ma Fengbo, Zhou Kun, Zhao Zheng, Shen Chenguang, Liao Yuhui

СтатьяПеревод в очереди

Аннотация

The recent monkeypox outbreak is garnering attention, but early warning and treatment mechanisms are lacking. Owing to its rapid spread and high death rate, monkeypox must be prevented and controlled immediately. An advanced early warning system for monkeypox prevention and control is provided through aggregation-induced emission luminogen (AIEgen)-active monitoring and precision photodynamic therapy (PDT). This system are developed by combining a sprayable AIE@LD with a commercial liquid dressing (LD) and a pyridine-substituted benzothiadiazole derivative possessing AIEgen properties. In vivo tests revealed that 1 min of low-power white light PDT at 5 mW cm- 2 promoted viral eradication and lesion healing within one week. The system comprises dual optical channels that incorporate smartphone image recognition software and a cloud platform, combining image analysis, data transmission, infection monitoring, and PDT to provide a comprehensive solution for detecting, monitoring, treating, and interrupting the transmission of monkeypox. This system can considerably reduce the medical burden of monkeypox epidemics and provide innovative ideas and technological assistance for intelligent prevention and management.

Для цитирования: Wang Wei, Liu Zining, Li Mengjun, Zheng Judun, Zhang Ruilin, Liu Ke, Li Xiaoxue, Wen Shaoying, Yu Jingze, Pan Meijia, Ma Fengbo, Zhou Kun, Zhao Zheng, Shen Chenguang, Liao Yuhui. AIEgen-Based Proactive Early Warning System and Precise Treatment Strategy for Monkeypox Prevention and Control.. Advanced science (Weinheim, Baden-Wurttemberg, Germany). 2025. DOI: 10.1002/advs.202515865.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.