MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1023/a:1018901826635

Медицинская библиотека · Pharmaceutical research · 1992

Development and evaluation of a novel dissolution apparatus for medicated chewing gum products.

Rider J N, Brunson E L, Chambliss W G, Cleary R W, Hikal A H, Rider P H, Walker L A, Wyandt C M, Jones A B

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

A novel dissolution apparatus was developed for medicated chewing gum products. A prototype gum product containing phenylpropanolamine hydrochloride (PPA) was used to evaluate the apparatus. The apparatus consists of a conical Teflon base and a rotating, ribbed Teflon plunger suspended in a dissolution vessel. Parameters evaluated were rotation speed, plunger frequency, medium volume, medium type, medium sampling location, number of plunger ribs, and number of gum pieces. Samples were taken over a 20-min period and samples were analyzed by HPLC. Cumulative percentage released-versus-time profiles were obtained for each parameter evaluated. Statistical analysis of the gum product indicated that the only significant differences occurred at the lowest rotation speed and lowest plunger frequencies. A Level A correlation was found between the in vitro release profile for the 20-rpm and 30-cycles/min plunger frequency and the in vivo chew-out study.

Для цитирования: Rider J N, Brunson E L, Chambliss W G, Cleary R W, Hikal A H, Rider P H, Walker L A, Wyandt C M, Jones A B. Development and evaluation of a novel dissolution apparatus for medicated chewing gum products.. Pharmaceutical research. 1992. DOI: 10.1023/a:1018901826635.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.