Left Atrial Appendage Exclusion Using the AtriClip Device: A Case Series.
Аннотация
BACKGROUND
Atrial fibrillation (AF) affects 1.5-2% of the population and is associated with a five-fold increased lifetime risk of stroke [1]. The left atrial appendage (LAA) is the source of embolic strokes in up to 90% of patients with non-valvular AF with clots in the left atrium [2].
METHODS
We reviewed the clinical notes and echocardiographic findings of 20 patients who underwent open cardiac surgery in which concurrent AtriClip (Atricure Inc, Westchester, OH, USA) device insertion was attempted at our institution from July 2013 to February 2015. This was to examine the safety and efficacy of LAA exclusion with clip devices during open cardiac surgery. Indications for LAA exclusion included a history or suspicion of atrial arrhythmia, left ventricular dilatation, or a history of transient ischaemic attacks.
RESULTS
All 20 of the 20 participants had successful placement of the clip device (100% success rate). There were no adverse events related to the device and no perioperative mortality. There were three late deaths due to chronic obstructive pulmonary disease (COPD), leukaemia, and refractory congestive cardiac failure. No late device related complications were found on follow-up imaging in the remaining patients.
CONCLUSIONS
The results of our study demonstrate the LAA exclusion during open cardiac surgery with the AtriClip device is safe, has a 100% success rate, and appears to be stable over time.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.