MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.biomaterials.2010.04.066

Медицинская библиотека · Biomaterials · 2010

Iodinated blood pool contrast media for preclinical X-ray imaging applications--a review.

Hallouard François, Anton Nicolas, Choquet Philippe, Constantinesco André, Vandamme Thierry

СтатьяОбзорПеревод в очереди

Аннотация

The in vivo X-ray micro-computed tomography (micro-CT) is a very powerful and non-invasive tool used to establish high-resolution images with isotropic voxels in typical scan times ranging from minutes to tenths of minutes. This preclinical imaging technology is primarily adapted to visualize bones. X-ray imaging of soft tissues is made possible by using opaque compounds, providing contrast through tissue vascularization. Thus, using control agents with a long-lasting time in the blood, active or passive targeting of soft tissue is made possible in small animals. In this respect, the use of hydrophilic iodinated X-ray contrast media remains limited due to their rapid blood clearance, albeit at a slightly slower pace in humans as compared with rodents. The development of an iodinated contrast medium with increased vascular residence time is thus necessary. This is precisely the scope of the present paper, which will review and compare in detail the different vectors used as long-circulating iodinated contrast agents for micro-CT, i.e. liposomes, nanoemulsions, micelles, dendrimers and other polymeric particles. The discussion is focused, for each of these nanoparticulate systems, on their method of formulation and production, their stability properties, encapsulation properties, release properties, pharmacokinetics, and toxicology. The different aspects relative to the adaptation of these properties and physico-chemical characteristics for blood pool contrast agents aimed at angiographic micro-CT applications are also discussed. The aim of this review is to propose an overview into the formulation and properties of iodinated micro-CT contrast agents for preclinical applications.

Для цитирования: Hallouard François, Anton Nicolas, Choquet Philippe, Constantinesco André, Vandamme Thierry. Iodinated blood pool contrast media for preclinical X-ray imaging applications--a review.. Biomaterials. 2010. DOI: 10.1016/j.biomaterials.2010.04.066.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.