MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1117/1.jbo.31.10.106001

Медицинская библиотека · Journal of biomedical optics · 2026

Spatio-temporally modulated fluorescence imager for intraoperative nerve identification.

Park Jesung, Yoo Hyejin, Streeter Samuel S, Grimble John, Scimone Mark T, Maguluri Gopi, Campbell Jeffrey L, O'Shaughnessy Madelyn, Iftimia Nicusor, Henderson Eric R, Pogue Brian W, Zhao Youbo

СтатьяПеревод в очереди

Аннотация

SIGNIFICANCE: Fluorescence-guided surgery (FGS) based on nerve-labeling agents has the potential to enhance nerve identification during various operational procedures including orthopedic, craniofacial, and otolaryngological surgeries that involve complex and delicate nerve structures. A major challenge in FGS is the adverse impact of strong ambient light, which interferes with weak fluorescence signals, especially at visible wavelengths. Currently, this issue is mitigated by dimming or turning off the operating room (OR) lights during the fluorescence imaging procedure. However, this causes substantial disruption to the surgical workflow and reduces the potential for clinical adoption of FGS technologies.

AIM: In this work, we develop a novel intraoperative fluorescence imager that is based on a spatio-temporal modulation (STM) approach to suppress interference from strong OR lights.

APPROACH: The STM technology employed a line-scan imaging scheme that encodes the fluorescence signal into a distinctive spatial frequency within a narrow time window. By applying spatial frequency demodulation and time-gating methods, the imager effectively extracted the fluorescence signals by rejecting temporally constant and spatially uniform background OR lights.

RESULTS

The performance of the imager in detecting nerve structures in realistic OR lighting conditions was validated during in vivo animal studies. Additional evaluation using ex vivo human nerve tissue specimens and perfused amputated human limbs further supported the clinical suitability and readiness.

CONCLUSIONS

This innovative imaging technology enables high-contrast fluorescence visualization of nerve tissue under standard OR lighting and represents a significant step toward practical clinical implementation of FGS for enhanced nerve identification.

Для цитирования: Park Jesung, Yoo Hyejin, Streeter Samuel S, Grimble John, Scimone Mark T, Maguluri Gopi, Campbell Jeffrey L, O'Shaughnessy Madelyn, Iftimia Nicusor, Henderson Eric R, Pogue Brian W, Zhao Youbo. Spatio-temporally modulated fluorescence imager for intraoperative nerve identification.. Journal of biomedical optics. 2026. DOI: 10.1117/1.jbo.31.10.106001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.