m+Medelevator.RU
← Поиск публикаций
Journal of infection and chemotherapy : official journal of the Japan Society of Chemotherapy · 2026

Comparison of area under the concentration-time curve estimations between Practical Antimicrobial Therapeutic Drug Monitoring (PAT) versions 3 and 4 for vancomycin using two-point sampling.

СтатьяНаблюдательное исследованиеСравнительное исследованиеМногоцентровое исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Suzuki Ayako, Fujihara Hisato, Yamaguchi Fumihiro, Yoshida Hiroaki, Tanaka Hiroaki, Ishigo Tomoyuki, Fujii Satoshi, Ebihara Fumiya, Maruyama Takumi, Yagi Yusuke, Hamada Yukihiro, Nagumo Fumio, Samura Masaru, Komatsu Toshiaki, Tomizawa Atsushi, Chiba Hiroaki, Takuma Akitoshi, Nishi Yoshifumi, Igarashi Yuki, Enoki Yuki, Matsumoto Kazuaki

Аннотация

Practical Antimicrobial Therapeutic Drug Monitoring (PAT) for vancomycin using Bayesian estimation is recommended for calculating the area under the concentration-time curve (AUC). In 2025, PAT was updated from version 3 to version 4, but differences in AUC estimations between these versions have not been examined. This study aimed to compare AUC estimations from both versions in the same patients. We conducted a multicenter, retrospective, observational study involving adult patients who received vancomycin treatment between September 2020 and December 2023, who underwent two-point sampling for initial TDM. AUC was calculated using both versions in three phases: 0-24 h (AUC0-24), 24-48 h (AUC24-48), and at steady state (AUCss). The sample included 894 cases. AUC values from versions 3 and 4 showed a high correlation (r = 0.947-0.964), but phase-related differences emerged. Version 4 yielded significantly lower AUC0-24 and AUC24-48 values (median: 420.7 μg h/mL vs 373.5 μg h/mL, p < 0.001; 398.9 μg h/mL vs 379.8 μg h/mL, p < 0.001), while AUCss was significantly higher in version 4 (448.4 μg h/mL vs 498.2 μg h/mL, p < 0.001). Since differences in population pharmacokinetic models can affect estimation results, clinicians should be aware that AUC estimations may vary depending on the PAT version used, and the results should be interpreted with caution.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты