m+Medelevator.RU
← Поиск публикаций
Diabetes & metabolism · 2026

Clinical effectiveness of different advanced hybrid closed-loop systems on time in tight range in adults with type 1 diabetes: A multicenter real-world study.

СтатьяМногоцентровое исследованиеНаблюдательное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Gonzalez-Maroto Ignacio, Moreno-Fernandez Jesus, Beato-Víbora Pilar Isabel, Quirós Carmen

Аннотация

INTRODUCTION: Advanced hybrid closed-loop systems (AHCL) systems are the preferred insulin delivery method for people with type 1 diabetes (PwT1D). Time in tight range (TITR) is becoming a new target for glycemic control. The ability of different AHCL systems to achieve an improvement in TITR remains unclear.

METHOD: Multicenter observational cross-sectional study to analyze the effect on TITR of the three different AHCL systems marketed in Spain: MM780G with SmartGuard (MM780G), Tandem t:slim X2 with Control-IQ (Control-IQ) and Ypsopump with CamAPS FX (CamAPS). PwT1D ≥ 18 yrs and treated with the same AHCL device for at least 3 months were recruited consecutively. The main objective was to analyze the differences in TITR between the three types of AHCL.

RESULTS: A total of 189 patients (female 66.8%) were recruited. Mean age was 42.8 ± 12.8 yrs. (18-72 yrs.) and T1D duration 23.5 ± 11.8 yrs. Time on AHCL automatization was 94.6 ± 7.6%. Overall TITR was 51.7 ± 11.6% with no between-group differences (P = 0.154). Notably, nocturnal TITR was higher with CamAPS (53.6 ± 15.4%, P = 0.029), compared to MM780G (45.9 ± 17.8%, P = 0.029) and Control-IQ (50.6 ± 15.4%, P = 0.029). However, time below range level 1 and 2 was higher among CamAPS group (3.9 ± 2.8% and 0.7 ± 1.0%, respectively; P < 0.001), compared to MM780G (1.6 ± 1.6% and 0.2 ± 0.3%, respectively; P < 0.001) and Control-IQ (2.5 ± 2.0% and 0.5 ± 0.5%, respectively; P < 0.001). HbA1c was higher in MM780G treated patients, compared to both Control-IQ and CamAPS (6.9 ± 0.7% vs. 6.5 ± 0.6%, P = 0.003).

CONCLUSION: AHCL systems are useful for achieving TITR >50%, with no differences between treatment groups. However, this study has detected differences in some aspects of glycemic control between the devices used which could have clinical implications.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты