DOI 10.1186/s44156-025-00100-4

Медицинская библиотека · Echo research and practice · 2025

Development of a screening checklist to identify individuals with suspected allergy to polyethylene glycol.

Strom Jordan B, Spetko Nicholas, Song Yang, Angell-James Constance E M, Cassidy Madeline A, Stout Jessica L, Winburn Morgan L, Lee Rebecca, Stone Cosby A

Письмо в редакциюПеревод в очереди

Аннотация

BACKGROUND

Polyethelene glycol (PEG) is a key component of several ultrasound enhancing agents (UEA) but has been recognized as contributing to anaphylactoid reactions, resulting in new contraindications to use in those with known or suspected PEG allergy. Despite these recommendations, no clinical tools currently exist to screen for those with suspected PEG-allergy in echocardiography laboratories.

METHODS

We developed a screening survey to identify patients with potential PEG allergy and prospectively implemented it in a pilot study involving 8 patients with confirmed PEG allergy by skin prick testing and 50 prospectively enrolled patients undergoing clinically-indicated echocardiography without known PEG allergy, June - July 2025.

RESULTS

All patients completed the survey. A positive response to at least 2 of the first 4 questions on the screening survey had a sensitivity of 100% (95% CI 67.6-100%), specificity of 100% (95% CI 92.9-100%), positive predictive value of 100% (95% CI 67.6-100%), and a negative predictive value of 100% (95% CI 92.9-100%) to identify individuals with known PEG allergy.

CONCLUSIONS

In this pilot multicenter study, a brief screening survey identified all patients with proven allergy to PEG, suggesting possible utility to its use to identify those with potential PEG allergy who would benefit from a non-PEGylated UEA, though further clinical validation is needed.

Для цитирования: Strom Jordan B, Spetko Nicholas, Song Yang, Angell-James Constance E M, Cassidy Madeline A, Stout Jessica L, Winburn Morgan L, Lee Rebecca, Stone Cosby A. Development of a screening checklist to identify individuals with suspected allergy to polyethylene glycol.. Echo research and practice. 2025. DOI: 10.1186/s44156-025-00100-4.