Cognitive impairment after appropriate implantable cardioverter-defibrillator therapy for ventricular fibrillation.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Hałas Katarzyna, Krzyżanowski Krystian, Krzyżanowska Ewa, Smurzyński Paweł, Ryczek Robert, Michałkiewicz Dariusz, Orski Zbigniew, Makowski Karol, Wierzbowski Robert, Gielerak Grzegorz

Аннотация

BACKGROUND: Short periods of cerebral ischaemia during ventricular defibrillation testing may be associated with neuropsychological impairment. However, the impact of out-of-hospital ventricular fibrillation (VF) converted by implantable cardioverter-defibrillator (ICD) shock on cognitive functioning is unknown.

AIM: To assess the impact of out-of-hospital VF converted by ICD shock on cognitive functioning.

METHODS: The study included 52 primary prevention ICD recipients. Patients with a history of stroke or other neurological impairment, previous head injury and individuals unable to see or speak to complete neuropsychological tests were not included.Initially, a Mini-Mental State Examination was performed in all patients and one patient with a result below 24 points was excluded from the study. The cognitive battery consisted of four tests (six measurements): 1) the Digit Span subtest of Wechsler Adult Intelligence Scale-Revised; 2) the Digit Symbol subtest of Wechsler Adult Intelligence Scale-Revised; 3) the Halstead-Reitan Trail-Making Test A and B; and 4) the Ruff Figural Fluency Test.

RESULTS: The mean time from ICD implantation to cognitive assessment was 26 months. During this period, 15 appropriate shocks for VF were observed in seven (14%) patients. The patients with appropriate ICD therapy were significantly worse in two out of the six neuropsychological measurements and had a significantly lower aggregate result. In multivariate linear regression analysis, defibrillation therapy was an independent factor of poor cognitive functioning, along with age and education.

CONCLUSIONS: Short periods of out-of-hospital VF converted by ICD are associated with cognitive impairment in the recipients of primary prevention ICD.