Frequency and prognosis of delayed facial palsy after microvascular decompression for hemifacial spasm.
Аннотация
BACKGROUND
Microvascular decompression (MVD) for hemifacial spasm (HFS) provides a long-term cure rate. Delayed facial palsy (DFP) is not an unusual complication, but it has only been sporadically described in the literature. The purpose of this report is to evaluate the incidence of delayed facial palsy after MVD and its clinical course and final results.
METHODS
From January, 1998 to April, 2004, 410 patients underwent microvascular decompression for hemifacial spasm at our Institute. During this time, 21 patients (5.4%) developed delayed facial weakness; eighteen of them were given steroid medication and they were followed up in the out-patient clinic.
FINDINGS: Twenty-one patients developed DFP after microvascular decompression an incidence of 5.4%. There were seventeen women (81.0%) among the 21 patients with DFP who were included in this study. In twenty of them, the symptoms of HFS improved completely after the operation, but the spasm remained with one of them. The onset of palsy occurred between postoperative day 7 and 23 (average: 12.1 days). The palsy was at least Grade II or worse on the House-Brackmann (HB) scale. The time to recovery averaged 5.7 weeks (range: 25 days-17 weeks); 20 patients improved to complete recovery and 1 patient remained with minimal weakness, as Grade II on the HB scale, at the follow-up examination.
CONCLUSION
Our findings demonstrated that the incidence of DFP was not so low as has been reported the literature, and it did not have any striking predisposing factors. Even though the degree of facial palsy was variable, almost all patients exhibited a complete recovery without any further special treatment. The etiology of DFP and its association with herpes infection should be further clarified.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.