MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/pace.70038

Медицинская библиотека · Pacing and clinical electrophysiology : PACE · 2025

Expected Benefits From Antibacterial Envelope in Different CIED Patient Populations.

Duncker David, Alonso Christine, Biffi Mauro, Costa Francisco, Bouazzaoui Rim El, Flevari Panagiota, Frausing Maria Hee Jung Park, Goette Andreas, Klug Didier, Maclean Edward, Tönnis Tobias, Trucco Emilce, Turley Andrew J, Wright Jay, Valente Bruno, Ziacchi Matteo

СтатьяОбзорПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Antibacterial envelope has proven to be safe and effective in reducing cardiac implantable electronic device (CIED) infection. Recently, its role in pocket healing process has also started to be studied, showing additional potential benefits for the patients. Risk scores such as the PADIT and the BLISTER ones have been developed to stratify patients at higher risk of developing CIED infections, but their use is still limited. There is a need for clear and concise practical guidance and scores for the correct stratification of patients at risk to develop CIED infections, to apply an effective preventive strategy. This article examines the most recent findings on the effectiveness of antibacterial envelopes in preventing CIED infections and introduces the latest concept of pocket stabilization. Additionally, patient populations that could potentially benefit from antibacterial envelope for both indications are provided based on the agreement of an expert panel made up of 16 European electrophysiologists from high-volume centers. Future studies will have to evaluate the strength of those proposals and the benefits of pocket stabilization in the long-term.

Для цитирования: Duncker David, Alonso Christine, Biffi Mauro, Costa Francisco, Bouazzaoui Rim El, Flevari Panagiota, Frausing Maria Hee Jung Park, Goette Andreas, Klug Didier, Maclean Edward, Tönnis Tobias, Trucco Emilce, Turley Andrew J, Wright Jay, Valente Bruno, Ziacchi Matteo. Expected Benefits From Antibacterial Envelope in Different CIED Patient Populations.. Pacing and clinical electrophysiology : PACE. 2025. DOI: 10.1111/pace.70038.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.