m+Medelevator.RU
← Поиск публикаций
The Laryngoscope · 2019

The Utility and Feasibility of Extending Beyond Traditional Patient Descriptions in Daily Practice.

Оценочное исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Shin Jennifer J, Carroll Thomas L, Prince Anthony A, Landman Adam B

Аннотация

OBJECTIVES/HYPOTHESIS: Institutional and national programs have endorsed the use of validated instruments in daily practice, but their utility for frontline clinicians is unknown. Our first objective was thus to determine if routinely obtained patient descriptions accurately predict disease-specific validated instrument results. Our second objective was to assess the feasibility of deploying an electronic system to obtain and document patient-reported descriptions of health status.

STUDY DESIGN: Prospective assessment of consecutive eligible ambulatory care patients.

METHODS: For the first objective, patients presenting with the same chief complaint at consecutive visits provided concurrent routine symptom descriptions and validated instrument responses. To determine whether patients' routine descriptions predicted scores from disease-specific instruments, receiver operator characteristic (ROC) curves, sensitivity/specificity, Spearman ρ correlation, and regression models were utilized. For the second objective, feasibility assessment focused on percent with successful response capture, time to questionnaire completion, and impact on physician time needed to obtain and document patient histories.

RESULTS: For the first objective, among patients with hearing loss, eustachian tube dysfunction, nasal obstruction, and chronic rhinosinusitis, the areas under the ROC curves were 0.38 to 0.83. Spearman ρ coefficients were 0.25 to 0.46. Sensitivity and specificity ranged from 15.9% to 87.8%, with correct classification in 42.3% to 55.2% of cases. For the second objective, there was a 91% completion rate. Completion times were 7:18 to 12:37 for new patients and 3:23 to 6:41 for established patients. Physician time savings were estimated at 11 minutes per patient.

CONCLUSIONS: Using validated instruments and electronic data collection systems in daily practice has practical and clinical implications. These topics warrant further study.

LEVEL OF EVIDENCE: 2c Laryngoscope, 130:S1-S13, 2020.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты