m+Medelevator.RU
← Поиск публикаций
PloS one · 2016

Adding Papillomacular Bundle Measurements to Standard Optical Coherence Tomography Does Not Increase Sensitivity to Detect Prior Optic Neuritis in Patients with Multiple Sclerosis.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Laible Mona, Jarius Sven, Mackensen Friedericke, Schmidt-Bacher Annette, Platten Michael, Haas Jürgen, Albrecht Philipp, Wildemann Brigitte

Аннотация

PURPOSE: To improve the detection of retinal nerve fiber layer (RNFL) thinning in multiple sclerosis (MS), a special peripapillary ring scanning algorithm (N-site RNFL, N-RNFL) was developed for spectral domain optical coherence tomography (SD-OCT). In contrast to the standard protocol (ST-RNFL) scanning starts nasally, not temporally, and provides an additional sector of analysis, the papillomacular bundle (PMB). We aimed to ascertain whether the temporal RNFL differs between the two techniques, whether N-RNFL is more sensitive than ST-RNFL to detect previous optic neuritis (ON), and whether analyzing the PMB adds additional sensitivity. Furthermore, we investigated whether RNFL is associated with disease severity and/or disease duration.

METHODS: We conducted a cross-sectional case-control study of 38 patients with MS, of whom 24 had a history of ON, and 40 healthy controls (HC). Subjects with ON within the previous 6 months were excluded. Records included clinical characteristics, visual evoked potentials (VEP), and SD-OCT in both techniques.

RESULTS: In a total of 73 evaluable MS eyes, temporal N-RNFL was abnormal in 17.8%, temporal ST-RNFL in 19.2%, and the PMB-RNFL in 21.9%. In ON eyes, the sensitivity of temporal N-RNFL and ST-RNFL did not differ significantly (37.0%/33.3%, p = 0.556). The sensitivity of VEP was 85.2%. RNFL thickness was associated with disease severity in all eyes, with and without a history of ON, and with disease duration.

CONCLUSION: The two OCT techniques detected previous ON with similar sensitivity, but the sensitivity of VEPs was superior to that of both N-RNFL and ST-RNFL. Our results indicate that the widely used ST-RNFL technique is appropriate for peripapillary RNFL measurements in MS patients.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты