MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.amjoto.2014.03.002

Медицинская библиотека · American journal of otolaryngology · 2014

The limitations of computed tomography in adult cochlear implant evaluation.

Sweeney Alex D, Carlson Matthew L, Rivas Alejandro, Bennett Marc L, Haynes David S, Wanna George B

Клинический случайСтатьяПеревод в очереди

Аннотация

OBJECTIVE

To demonstrate the added value of magnetic resonance imaging (MRI) over computed tomography (CT) during adult cochlear implant evaluation.

PATIENTS: Two adult patients are discussed in whom MRI studies diagnosed bilateral vestibular schwannomas during cochlear implant candidacy evaluation.

INTERVENTIONS: Temporal bone CT and MRI.

MAIN OUTCOME MEASURE: Diagnosis of NF2.

RESULTS

Two adult patients, ages 67 and 68 years, were evaluated for cochlear implant candidacy. Both patients experienced slowly progressive, bilateral hearing loss without complaints of vertigo, and neither patient had a family history of hearing loss or neurogenic tumors. Both patients had near-symmetric pure tone thresholds on audiometric testing. An MRI and a CT scan were performed on both patients, and bilateral vestibular schwannomas were identified on MRI.

CONCLUSIONS

Though MRI is not routinely utilized in adult cochlear implant evaluation, it may be of greater clinical value than CT in the setting of adult-onset hearing loss. MRI allows for sensitive evaluation of cochlear patency and architecture, and cochlear nerve status. As demonstrated in the two index cases, MRI also provides the added benefit of evaluating for causes of retrocochlear hearing loss. These two patients would have likely experienced a significant delay in diagnosis of NF2 without preoperative MRI, particularly given the limitations of scanning following CI magnet placement.

Для цитирования: Sweeney Alex D, Carlson Matthew L, Rivas Alejandro, Bennett Marc L, Haynes David S, Wanna George B. The limitations of computed tomography in adult cochlear implant evaluation.. American journal of otolaryngology. 2014. DOI: 10.1016/j.amjoto.2014.03.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.