m+Medelevator.RU
← Поиск публикаций
Diabetes research and clinical practice · 2014

Longitudinal assessment of neuropathy in type 1 diabetes using novel ophthalmic markers (LANDMark): study design and baseline characteristics.

Контролируемое клиническое исследованиеСтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Pritchard Nicola, Edwards Katie, Dehghani Cirous, Fadavi Hassan, Jeziorska Maria, Marshall Andrew, Petropoulos Ioannis N, Ponirakis Georgios, Russell Anthony W, Sampson Geoff P, Shahidi Ayda M, Srinivasan Sangeetha, Tavakoli Mitra, Vagenas Dimitrios, Malik Rayaz A, Efron Nathan

Аннотация

AIMS: Corneal nerve morphology and corneal sensation threshold have recently been explored as potential surrogate markers for the evaluation of diabetic neuropathy. We present the baseline findings of the 'Longitudinal Assessment of Neuropathy in type 1 Diabetes using novel ophthalmic Markers'(LANDMark) study.

METHODS: The LANDMark study is a 4-year, two-site, natural history study of three participant groups: type 1 diabetes with neuropathy (T1W), type 1 diabetes without neuropathy (T1WO) and control participants without diabetes or neuropathy. All participants undergo a detailed annual assessment of neuropathy including corneal nerve parameters measured using corneal confocal microscopy and corneal sensitivity measured using non-contact corneal aesthesiometry.

RESULTS: 76 T1W, 166 T1WO and 154 control participants were enrolled into the study. Corneal sensation threshold was significantly higher (i.e., sensitivity was lower) in T1W (1.0±1.1mbars) than T1WO (0.7±0.7mbars) and controls (0.6±0.4mbars) (p<0.001), with no difference between T1WO and controls. Corneal nerve fibre length was lower in T1W (14.0±6.4mm/mm(2)) compared to T1WO (19.1±5.8mm/mm(2)) and controls (23.2±6.3mm/mm(2)) (p<0.001). Corneal nerve fibre length was lower in T1WO compared to controls.

CONCLUSIONS: The LANDMark baseline findings confirm a reduction in corneal sensitivity only in Type 1 patients with neuropathy. However, corneal nerve fibre length is reduced in Type 1 patients without neuropathy with an even greater deficit in Type 1 patients with neuropathy.

Предметные рубрики MeSH