MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/1352458513512708

Медицинская библиотека · Multiple sclerosis (Houndmills, Basingstoke, England) · 2013

Pupillary response to sparse multifocal stimuli in multiple sclerosis patients.

Ali E N, Maddess T, James A C, Voicu C, Lueck C J

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

The objective of this paper is to investigate the pattern of abnormalities and establish the diagnostic power of multifocal objective pupil perimetry (mfPOP) in multiple sclerosis (MS).

METHODS

A prospective study enrolling 35 normal (47.9 ± 16.8 years, 22 females) and 85 MS subjects (49.8 ± 11.3 years, 62 females; 72 relapsing-remitting (RR), and 13 primary or secondary progressives (PorS)). EDSS scores for the RR and PorS groups were 3.53 ± 1.04 (mean ± SD), and 5.9 ± 1.43, respectively. mfPOP responses were obtained from 44 regions/visual field. Each region was analysed according to response time-to-peak and standardised amplitude (AmpStd). Predictive power was measured by percentage area under the receiver operator curve (%AUC).

RESULTS

mfPOP responses showed a significant reduction of 0.69 ± 0.04 dB (mean ± SE) in AmpStd and significantly delayed time-to-peak of 25.95 ± 0.89 ms (mean ± SE) in MS subjects compared to control subjects (p<0.001). %AUC was greater for time-to-peak than AmpStd both for RR and PorS patients. Diagnostic power followed the EDSS scores but not a history of optic neuritis.

CONCLUSIONS

mfPOP is well tolerated and potentially has a role in the diagnosis and assessment of patients with MS.

Для цитирования: Ali E N, Maddess T, James A C, Voicu C, Lueck C J. Pupillary response to sparse multifocal stimuli in multiple sclerosis patients.. Multiple sclerosis (Houndmills, Basingstoke, England). 2013. DOI: 10.1177/1352458513512708.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.