Diagnosing preperimetric glaucoma with spectral domain optical coherence tomography.
Аннотация
PURPOSE: To evaluate the diagnostic accuracy of spectral domain optical coherence tomography (SD-OCT) for detection of preperimetric glaucoma and compare it with the performance of confocal scanning laser ophthalmoscopy (CSLO).
DESIGN
Cohort study.
PARTICIPANTS
A cohort of 134 eyes of 88 glaucoma suspects based on the appearance of the optic disc.
METHODS
Patients were recruited from the Diagnostic Innovations in Glaucoma Study (DIGS). All eyes underwent retinal nerve fiber layer (RNFL) imaging with Spectralis SD-OCT (Heidelberg Engineering, Carlsbad, CA) and topographic imaging with Heidelberg Retinal Tomograph III (HRT-III) (Heidelberg Engineering) CSLO within 6 months of each other. All patients had normal visual fields at the time of imaging and were classified on the basis of history of documented stereophotographic evidence of progressive glaucomatous change in the appearance of the optic nerve occurring before the imaging sessions.
MAIN OUTCOME MEASURES: Areas under the receiver operating characteristic curves (AUCs) were calculated to summarize diagnostic accuracies of the SD-OCT and CSLO. Likelihood ratios (LRs) were reported using the diagnostic categorization provided by each instrument after comparison to its normative database.
RESULTS
Forty-eight eyes of 42 patients had evidence of progressive glaucomatous change and were included in the preperimetric glaucoma group. Eighty-six eyes of 46 patients without any evidence of progressive glaucomatous change followed untreated for an average of 14.0 ± 3.6 years were included in the control group. The parameter with the largest AUC obtained with the SD-OCT was the temporal superior RNFL thickness (0.88 ± 0.03), followed by global RNFL thickness (0.86 ± 0.03) and temporal inferior RNFL thickness (0.81 ± 0.04). The parameter with the largest AUC obtained with the CSLO was rim area (0.72 ± 0.05), followed by rim volume (0.71 ± 0.05) and linear cup-to-disk ratio (0.66 ± 0.05). Temporal superior RNFL average thickness measured by SD-OCT performed significantly better than rim area measurements from CSLO (0.88 vs. 0.72; P=0.008). Outside normal limits results for SD-OCT parameters were associated with strongly positive LRs.
CONCLUSIONS
The RNFL assessment with SD-OCT performed well in detecting preperimetric glaucomatous damage in a cohort of glaucoma suspects and had a better performance than CSLO.