MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3109/00016489.2011.619570

Медицинская библиотека · Acta oto-laryngologica · 2011

Benign paroxysmal positional vertigo: is vestibular evoked myogenic potential testing useful?

Longo Giovanni, Onofri Marina, Pellicciari Teresa, Quaranta Nicola

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

CONCLUSIONS

In benign paroxysmal positional vertigo (BPPV), vestibular evoked myogenic potentials (VEMPs) help to better define the extent of saccular damage and the patient's prognosis.

OBJECTIVES

To report the results of VEMPs in patients affected by BPPV of the posterior semicircular canal (PSC) in order to evaluate the presence of signs of saccular dysfunction compared to the normal population and to correlate them with the clinical picture.

METHODS

This was a prospective study in a tertiary referral center; 23 patients affected by BPPV of the PSC and 24 controls were evaluated. All patients underwent complete clinical history and otoneurologic and audiovestibular evaluation consisting of pure-tone audiometry, caloric testing, and registration of VEMPs.

RESULTS

VEMP thresholds and latencies were not different between patients and controls. As a group BPPV patients presented significantly higher abnormal VEMPs compared with controls (p < 0.001). Age positively correlated with VEMP threshold in the affected ear of patients and in controls; the number of BPPV attacks positively correlated with threshold and negatively with amplitude of VEMPs in the affected ear; duration of the last attack was negatively correlated with the effect of the maneuver performed.

Для цитирования: Longo Giovanni, Onofri Marina, Pellicciari Teresa, Quaranta Nicola. Benign paroxysmal positional vertigo: is vestibular evoked myogenic potential testing useful?. Acta oto-laryngologica. 2011. DOI: 10.3109/00016489.2011.619570.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.