DOI 10.1016/j.ophtha.2010.02.024

Медицинская библиотека · Ophthalmology · 2010

Diagnostic validity of optic disc and retinal nerve fiber layer evaluations in detecting structural changes after optic neuritis.

Bertuzzi Francesca, Suzani Martina, Tagliabue Elena, Cavaletti Guido, Angeli Raffaella, Balgera Roberto, Rulli Eliana, Ferrarese Carlo, Miglior Stefano

СтатьяПоддержка исследования: вне правительства СШАВалидационное исследованиеПеревод в очереди

Аннотация

PURPOSE: To assess the diagnostic validity of morphometric examination of the optic disc and retinal nerve fiber layer (RNFL) thickness to detect permanent structural changes after retrobulbar optic neuritis (ON).

DESIGN

Evaluation of a diagnostic test.

PARTICIPANTS

Twenty-five patients with a history of retrobulbar ON and 29 disease-free controls.

METHODS

The optic discs were evaluated by means of confocal scanning laser ophthalmoscopy (Heidelberg Retinal Tomograph [HRT III]), and RNFL thickness by means of scanning laser polarimetry (GDx), and optical coherence tomography (OCT). Vision function was assessed in all subjects by testing visual acuity, contrast sensitivity, color vision, visual field (VF), and visual evoked potentials (VEPs). Statistical comparisons were made between the affected (ON) and unaffected eyes (non-ON) of the patients with ON, and between these eyes and control eyes (Mann-Whitney test and Wilcoxon's test). Receiver operating characteristic (ROC) curves, and sensitivity and specificity in discriminating ON from control eyes, were calculated for the significant parameters. Correlations between the tests were calculated by means of Spearman's correlation coefficient.

MAIN OUTCOME MEASURES: We compared OCT, GDx, HRT, and visual testing results in ON eyes versus control eyes.

RESULTS

All of the visual function test parameters and RNFL thickness (GDx and OCT) were significantly different between the ON eyes and both the non-ON and control eyes (P<0.01), and there were significant differences in some GDx parameters between the non-ON and control eyes. There were no significant differences in the HRT parameters. The ROC curves indicated that the greatest diagnostic validity was associated with the GDx nerve fiber indicator (AUC, 0.92; sensitivity, 0.80; specificity, 0.97 using a cutoff point of 20.5 between ON and non-ON eyes), and OCT temporal thickness (AUC, 0.92; sensitivity, 0.72; specificity, 0.95 using a cutoff point of 51.5 microm).

CONCLUSIONS

When investigating permanent damage after ON, RNFL thickness is a promising biomarker. The GDx and OCT are reliable, noninvasive, user-friendly devices; both show good diagnostic validity and good correlations with functional tests in discriminating affected from unaffected eyes. Retinal nerve fiber layer thinning in non-ON eyes should be further studied as a possible subclinical indicator of disease.

Для цитирования: Bertuzzi Francesca, Suzani Martina, Tagliabue Elena, Cavaletti Guido, Angeli Raffaella, Balgera Roberto, Rulli Eliana, Ferrarese Carlo, Miglior Stefano. Diagnostic validity of optic disc and retinal nerve fiber layer evaluations in detecting structural changes after optic neuritis.. Ophthalmology. 2010. DOI: 10.1016/j.ophtha.2010.02.024.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.