MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/s-2008-1027253

Медицинская библиотека · Klinische Monatsblatter fur Augenheilkunde · 2008

Pattern of macular thickness changes measured by ocular coherence tomography in patients with multiple sclerosis.

Gugleta K, Mehling M, Kochkorov A, Grieshaber M, Katamay R, Flammer J, Orgül S, Kappos L

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

An analysis of the pattern of retinal thickness changes in macula in patients with multiple sclerosis (MS) was performed.

PATIENTS AND

METHODS

In fifteen patients with MS retinal thickness measurements in the central (fovea plus inner macular ring) and peripheral (outer ring) macula obtained by ocular coherence tomography (OCT-3 device) were compared to those of 15 age-matched healthy controls.

RESULTS

Eyes of MS patients had on the average a thinner macula (241.8 +/- 20.6 micrometers) than control eyes (252.0 +/- 16.4, p value 0.038). Significant segmental differences occurred in the central macula (p = 0.013). Eight eyes with a positive history of optic neuritis (ON) had on average a thinner macula (226.8 +/- 14.0) than eyes of MS patients without a history of ON (non-ON eyes: 247.3 +/- 20.1, p value 0.01). The only measure significantly different between non-ON and control eyes was the ratio between the central and peripheral macular thickness (p = 0.017). Average macular thickness in non-ON eyes, unlike control eyes (r = - 0.63, p = 0.0002), did not correlate with age (r = 0.01, p = 0.97), however, it did show a borderline correlation with disease duration (r = - 0.41, p = 0.056).

CONCLUSIONS

Preferential thinning in the central relative to the peripheral macular region is present in eyes of patients with MS. The macular thickness pattern is likely due to the histological distribution of nerve fibre layer and retinal ganglion cell in the macular area and seems to be particularly informative of neurodegeneration in the eyes of MS patients without a history of optic neuritis.

Для цитирования: Gugleta K, Mehling M, Kochkorov A, Grieshaber M, Katamay R, Flammer J, Orgül S, Kappos L. Pattern of macular thickness changes measured by ocular coherence tomography in patients with multiple sclerosis.. Klinische Monatsblatter fur Augenheilkunde. 2008. DOI: 10.1055/s-2008-1027253.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.