MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1442-9071.2007.01457.x

Медицинская библиотека · Clinical & experimental ophthalmology · 2007

Glaucoma screening: analysis of conventional and telemedicine-friendly devices.

Kumar Sajeesh, Giubilato Antonio, Morgan William, Jitskaia Ludmila, Barry Chris, Bulsara Max, Constable Ian J, Yogesan Kanagasingam

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: Portable, telemedicine-friendly devices offer novel opportunity for screening and monitoring glaucoma in the remote and rural regions of the world. This study examines the effective combination of telemedicine-friendly screening devices for detection of glaucoma in relation with conventional, hospital-based devices.

METHODS

A total of 399 eyes were screened with telemedicine-friendly devices and conventional, hospital-based devices such as ophthalmoscope, tonometer and perimeter.

RESULTS

Combination of age and family history of glaucoma alone has a sensitivity of 35.6% (specificity 94.2%, area under the curve 0.81, correctly classified 81.1%) and an addition of telemedicine-friendly or conventional visual field tests optimized the sensitivity to 91.1% (specificity 93.6%, area under the curve 0.95, correctly classified 93%). Analysis indicates good agreement between vertical cup-to-disc ratio by ophthalmoscopy and digital image reading. An addition of intraocular pressure test does not change sensitivity (35.6%) and specificity (94.2%).

CONCLUSION

This study indicates that evaluations of cup-to-disc ratio and visual field, using telemedicine-friendly devices, are most useful tools in screening for glaucoma. When used together these devices may be an alternative for conventional glaucoma screenings.

Для цитирования: Kumar Sajeesh, Giubilato Antonio, Morgan William, Jitskaia Ludmila, Barry Chris, Bulsara Max, Constable Ian J, Yogesan Kanagasingam. Glaucoma screening: analysis of conventional and telemedicine-friendly devices.. Clinical & experimental ophthalmology. 2007. DOI: 10.1111/j.1442-9071.2007.01457.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.