m+Medelevator.RU
← Поиск публикаций
Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2025

Assessment of sestamibi CZT-SPECT reconstructed using deep-learning-based virtual attenuation correction maps according to coronary artery territory and with comparison to rubidium-PET.

Клиническое исследованиеСравнительное исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Sprauel Telma, Imbert Laetitia, Doyeux Kaya, Perrin Mathieu, Claudin Marine, Roch Véronique, Doyen Matthieu, Roth Nathaniel, Lamash Yechiel, Chequer Renata, Rouzet François, Hyafil Fabien, Marie Pierre-Yves

Аннотация

BACKGROUND: Attenuation artifacts affect the analysis of single-photon emission computed tomography (SPECT) myocardial perfusion imaging, especially in the right coronary artery (RCA) territory, although computed tomography (CT)-based attenuation corrections minimize this issue. This study aims to assess stress-rest [99mTc]sestamibi cadmium zinc telluride (CZT)-SPECT reconstructed using deep-learning-based attenuation correction (DLAC) maps according to coronary artery territory and with comparison to [82Rb]rubidium-positron emission tomography (Rb-PET) conventionally reconstructed with CT-based attenuation correction.

METHODS: We compared stress-rest [99mTc]sestamibi CZT-SPECT reconstructed without (i.e., standard (SD-SPECT)) and with DLAC (DLAC-SPECT) in 84 patients at risk of attenuation artifacts (overweight individuals and women) with no previous history of coronary artery disease (CAD), and who also had Rb-PET and, when indicated, coronary angiography.

RESULTS: In 74 very low CAD-risk patients: (i) the stress segmental activity values were homogeneous between the three coronary artery territories with DLAC-SPECT and Rb-PET but exhibited a marked reduction in the RCA territory with SD-SPECT (69.1% ± 8.2% vs 81.2% ± 7.1% and 77.7% ± 8.5% for DLAC-SPECT and Rb-PET, respectively, both P < .001), and (ii) the absolute value of the difference between the rest and stress segmental activities was higher in the RCA territory with SD-SPECT (5.13% ± 4.04%) than with DLAC-SPECT (4.21% ± 3.24%) and Rb-PET (3.92% ± 3.08%, both P < .001).

CONCLUSIONS: When utilizing DLAC maps for reconstruction of [99mTc]sestamibi CZT-SPECT, there is no more drop in the RCA territory uptake with lower fluctuations in stress-to-rest activity, aligning closely with the results observed using Rb-PET in the same patients.

TRIAL REGISTRATION NUMBER: NCT01679886 on clinicaltrials.gov.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты