DOI 10.1016/j.jacep.2024.09.003
Long-Term Differences in Autonomic Alterations After Cryoballoon vs Radiofrequency Atrial Fibrillation Ablation.
Аннотация
BACKGROUND
The long-term natural history of autonomic alterations following catheter ablation of drug-refractory paroxysmal atrial fibrillation is poorly defined.
OBJECTIVES
The authors sought to define the long-term impact of thermal catheter ablation on the cardiac autonomic system.
METHODS
The study included 346 patients with drug-refractory paroxysmal atrial fibrillation undergoing pulmonary vein isolation using thermal ablation energy (radiofrequency or cryoballoon ablation). All patients underwent insertion of a Reveal LINQ implantable cardiac monitor prior to ablation. The implantable cardiac monitor continuously recorded physical activity, heart rate variability (HRV) (measured as the standard deviation of the average normal-to-normal), daytime heart rate, and nighttime heart rate (NHR). Longitudinal autonomic data in the 2-month period prior to the date of ablation were compared with the 3 years following ablation.
RESULTS
Following ablation, there was a significant decrease in HRV (10-20 ms; P < 0.0001) and significant increases in daytime heart rate and NHR (10 beats/min [P < 0.0001] and 7 beats/min [P < 0.0001], respectively). Changes in autonomic parameters were greatest in the first 3 months following ablation but remained significantly different from baseline for 36 months following ablation. Greater changes in NHR and HRV were associated with improved freedom from recurrent arrhythmia. The type of thermal ablation energy had no influence on the heart rate and autonomic parameters.
CONCLUSIONS
Pulmonary vein isolation using thermal ablation energy results in significant sustained changes in the heart rate parameters related to autonomic function. These changes are independent of the ablation technology employed and are associated with procedural success. (Cryoballoon vs Irrigated Radiofrequency Catheter Ablation: Double Short vs Standard Exposure Duration [CIRCA-DOSE]; NCT01913522).
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.