New-onset atrial fibrillation following left bundle branch area pacing vs. right ventricular pacing: a two-centre prospective cohort study.

Zhu Haojie, Li Xiaofei, Wang Zhao, Liu Qian, Chu Bingqian, Yao Yan, Liu Zhimin, Xie Ruiqin, Fan Xiaohan

СтатьяПеревод в очереди

Аннотация

AIMS: To investigate whether left bundle branch area pacing (LBBAP) can reduce the risk of new-onset atrial fibrillation (AF) compared with right ventricular pacing (RVP).

METHODS AND

RESULTS

Patients with indications for dual-chamber pacemaker implant and no history of AF were prospectively enrolled if they underwent successful LBBAP or RVP. The primary endpoint was time to the first occurrence of AF detected by pacemaker programming or surface electrocardiogram. Follow-up at clinic visit was performed and multivariate Cox regression models were applied to evaluate the effect of LBBAP on new-onset AF. The final analysis included 527 patients (mean age 65.3 ± 12.6, male 47.3%), with 257 in the LBBAP and 270 in the RVP groups. During a mean follow-up of 11.1 months, LBBAP resulted in significantly lower incidence of new-onset AF (7.4 vs. 17.0%, P < 0.001) and AF burden (3.7 ± 1.9 vs. 9.3 ± 2.2%, P < 0.001) than RVP. After adjusting for confounding factors, LBBAP demonstrated a lower hazard ratio for new-onset AF compared with RVP {hazard ratio (HR) [95% confidence interval (CI)]: 0.278 (0.156, 0.496), P < 0.001}. A significant interaction existed between pacing modalities and the percentage of ventricular pacing (VP%) (P for interaction = 0.020). In patients with VP ≥ 20%, LBBAP was associated with decreased risk of new-onset AF compared with RVP [HR (95% CI): 0.199 (0.105, 0.378), P < 0.001]. The effect of pacing modalities was not pronounced in patients with VP < 20% [HR (95% CI): 0.751 (0.309, 1.823), P = 0.316].

CONCLUSION

Left bundle branch area pacing demonstrated a reduced risk of new-onset AF compared with RVP. Patients with a high ventricular pacing burden might benefit from LBBAP.

Для цитирования: Zhu Haojie, Li Xiaofei, Wang Zhao, Liu Qian, Chu Bingqian, Yao Yan, Liu Zhimin, Xie Ruiqin, Fan Xiaohan. New-onset atrial fibrillation following left bundle branch area pacing vs. right ventricular pacing: a two-centre prospective cohort study.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2023. DOI: 10.1093/europace/euac132.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.