Impella 5.0 repositioning across the aortic valve without a guidewire using rapid ventricular pacing: A case report.
Аннотация
BACKGROUND
Displacement of Impella 5.0 secondary to patient movement or transportation is a well-known complication. Typically, repositioning of an Impella across the aortic valve is attempted over a guidewire. We present the first case, to our knowledge, of repositioning a dislodged Impella 5.0 without a guidewire under transesophageal echocardiography (TEE) guidance, by inducing rapid ventricular pacing to cross the aortic valve.
CASE PRESENTATION: A 70-year-old man with low left ventricular ejection fraction underwent off-pump coronary artery bypass grafting. On 2nd postoperative day a low cardiac output state developed with increasing lactate levels and consequently the patient was taken to the cardiac catheterization laboratory for insertion of an Impella 5.0. Suddenly the Impella system failed with a rapid hemodynamic deterioration and it was successfully bedside repositioned inducing rapid ventricular pacing.
CONCLUSIONS
In case of accidental Impella dislodgement and fast deterioration of the patient's hemodynamic status, rapid pacing may be an option to "open" the aortic valve thus aiding quick replacement of Impella 5.0 through the aortic valve into the left ventricle under TEE guidance.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.