Total pulmonary artery replacement with an Avalus-Gelweave conduit in a patient with giant pulmonary artery aneurysm with pulmonary regurgitation.

Qian Qi, Subbian Senthil Kumar, Kofidis Theo

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND AND AIMS: Pulmonary artery aneurysm is a rare disease. A 59-year-old Chinese female was diagnosed with idiopathic pulmonary aneurysm with pulmonary regurgitation. She had a past medical history of hemoptysis and systemic lupus erythematosus.

METHODS

She underwent a successful total pulmonary artery and valve replacement with an Avalus-Gelweave conduit.

RESULTS

The postoperative echocardiogram showed a 7 mm Hg peak gradient across the prosthetic valve. The patient's postoperative recovery was uncomplicated.

CONCLUSIONS

A bioprosthetic aortic valve can be used in a pulmonary position to achieve a good gradient and avoid long term anticoagulation therapy.

Для цитирования: Qian Qi, Subbian Senthil Kumar, Kofidis Theo. Total pulmonary artery replacement with an Avalus-Gelweave conduit in a patient with giant pulmonary artery aneurysm with pulmonary regurgitation.. Journal of cardiac surgery. 2020. DOI: 10.1111/jocs.14517.