Progression of ascending aortopathy may not occur after transcatheter aortic valve replacement in severe bicuspid aortic stenosis.

Jung Ji-Hyun, Kim Hyung-Kwan, Park Jun-Bean, Lee Seung-Pyo, Koo Bon-Kwon, Kim Yong-Jin, Kim Hyo-Soo, Sohn Dae-Won

СтатьяПеревод в очереди

Аннотация

BACKGROUND/AIMS: We evaluated changes in the ascending aorta dimension post-transcatheter aortic valve replacement (TAVR) in bicuspid aortic valve (BiAV) and tricuspid aortic valve (TAV) patients.

METHODS

Patients with severe aortic stenosis undergoing TAVR at Seoul National University Hospital were consecutively recruited. Patients with less than 12 months' follow-up and/or with an ascending aorta size larger than 50 mm were excluded. The ascending aorta size was measured on a parasternal long axis view using transthoracic echocardiography.

RESULTS

Among the 67 patients who were included (age: 76.5 ± 6.5 years; male: 52.2%; AV area: 0.67 ± 0.15 cm2), 19 (28.4%) had BiAV; 48 (71.6%) had TAV. The median (interquartile ranges) follow-up duration was 398 days (361 to 451). BiAV patients were younger (73.2 ± 7.2 vs. 77.8 ± 5.8, p = 0.008), and had lower incidences of chronic renal disease (5.3% vs. 35.4%, p = 0.014) and history of coronary intervention (15.8% vs. 50.0%, p = 0.013), than TAV patients. On pre-procedural echocardiography, the ascending aorta dimensions in BiAV patients were larger than those in TAV patients (40.5 ± 3.8 mm vs. 35.9 ± 4.2 mm, p < 0.005). The ascending aorta dimension changed minimally during follow-up; post-TAVR, the ascending aorta's growth rate was -0.11 ± 1.9 and 0.26 ± 1.8 mm/yr in patients with BiAV and TAV, respectively (p = 0.50). Progression of the ascending aorta's dimension postTAVR was not clinically significant in BiAV patients.

CONCLUSION

The concern about the progression of aortopathy in BiAV patients post-TAVR may not be a clinical issue. This should be confirmed in studies with a larger population and with a longer follow-up duration.

Для цитирования: Jung Ji-Hyun, Kim Hyung-Kwan, Park Jun-Bean, Lee Seung-Pyo, Koo Bon-Kwon, Kim Yong-Jin, Kim Hyo-Soo, Sohn Dae-Won. Progression of ascending aortopathy may not occur after transcatheter aortic valve replacement in severe bicuspid aortic stenosis.. The Korean journal of internal medicine. 2019. DOI: 10.3904/kjim.2019.089.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.