MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.aca.2024.343415

Медицинская библиотека · Analytica chimica acta · 2024

Automatic and integrated detection of nucleic acid by using a dual-mode thermal controlled digital microfluidic chip.

Liao Jiaqi, Li Chonghao, Liu Jiajia, Cheng Hao, Li Linmin, Tang Guixi, Huang Ru, Lu Yating, Chen Siyue, Zhang Qian, Chen Hao, Chen Qinyuan, Chen Hong, Sun Daoheng

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

The detection of nucleic acids, which typically consists of nucleic acid extraction, reverse transcription and amplification, is a crucial component of molecular diagnostics. However, traditional methods have several limitations, including high reliance on skilled personnel, low degree of automation and lengthy assay times. Additionally, these methods also require separate areas for the different steps to avoid contamination. Though a number of digital microfluidic (DMF) chips have been reported to detect the nucleic acids, but there is a noticeable absence of fully integrated DMF platforms capable of concurrently performing nucleic acid extraction, amplification, and signal detection. Here, a DMF chip combined with a dual-mode thermal control module was developed to realize the automatic and integrated detection of nucleic acids. The dual-mode thermal control module provided the required temperatures (with a range from 4 °C to 95 °C) for all the steps of nucleic acid detection. Pseudoviruses of SARS-CoV-2 and monkeypox were chosen to demonstrate the feasibility of the DMF chip, and all assays were completed within 40 min. The results confirmed that the products extracted under 4 °C exhibited high concentration and integrity, which were comparable to those by traditional methods. And the analytical performance of amplify was comparable to that of traditional methods with a more compact design, shorter time, smaller size and more automatic operation. With the ability of dual-mode thermo control and full automatic operation, nucleic acid detection with the characteristics of sample-in-result-out was realized on the DMF chip, which holds great promise in fields such as in vitro diagnostics and point-of-care testing.

Для цитирования: Liao Jiaqi, Li Chonghao, Liu Jiajia, Cheng Hao, Li Linmin, Tang Guixi, Huang Ru, Lu Yating, Chen Siyue, Zhang Qian, Chen Hao, Chen Qinyuan, Chen Hong, Sun Daoheng. Automatic and integrated detection of nucleic acid by using a dual-mode thermal controlled digital microfluidic chip.. Analytica chimica acta. 2024. DOI: 10.1016/j.aca.2024.343415.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.