MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.cjca.2018.11.014

Медицинская библиотека · The Canadian journal of cardiology · 2018

Prospective Study of Tricuspid Regurgitation Associated With Permanent Leads After Cardiac Rhythm Device Implantation.

Van De Heyning Caroline M, Elbarasi Esam, Masiero Simona, Brambatti Michela, Ghazal Sami, Al-Maashani Said, Capucci Alessandro, Leong Darryl, Shivalkar Bharati, Saenen Johan B, Miljoen Hielko P, Morillo Carlos A, Divarakarmenon Syamkumar, Amit Guy, Ribas Sebastian, Baiocco Erika, Maolo Alessandro, Romandini Andrea, Maffei Simone, Connolly Stuart J, Healey Jeff S, Dokainish Hisham

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Tricuspid regurgitation (TR) has been associated with cardiac rhythm device (CRD) implantation with intracardiac lead insertion. However, data on the incidence of postdevice TR are limited and largely from retrospective studies. We hypothesized that permanent lead implantation would be associated with an increase in TR.

METHODS

We prospectively included consecutive patients with a clinical indication for CRD. Patients underwent transthoracic echocardiography 1 month before and 1 year after CRD implantation.

RESULTS

A total of 328 patients were prospectively enrolled (69 ± 15 years, 38% female). Echocardiograms before and 1 year after CRD were available in 290 patients (15 died, 23 lost to follow-up). Compared with baseline, there was a significant change in TR grade 1 year after CRD insertion (no/trivial TR: 66% vs 29%; mild TR: 29% vs 61%; moderate TR: 3% vs 8%; severe TR 2% vs 2%; P < 0.001 for an increase in TR by at least 1 grade). Compared with baseline, there was a higher prevalence of moderate or severe TR in the 247 patients with CRD without cardiac resynchronization therapy (4% vs 10%, P = 0.004), but no progression in the 43 patients who received cardiac resynchronization therapy (14% vs 11%, P = 1). Multivariable analysis in the patients with less than moderate TR at baseline (n = 274) showed that only a history of atrial fibrillation was independently associated with progression to moderate or severe TR after correction for baseline TR grade (P = 0.013).

CONCLUSIONS

One year after endocardial lead insertion, there was a 5% increase in the prevalence of moderate or severe TR, which may be clinically relevant.

Для цитирования: Van De Heyning Caroline M, Elbarasi Esam, Masiero Simona, Brambatti Michela, Ghazal Sami, Al-Maashani Said, Capucci Alessandro, Leong Darryl, Shivalkar Bharati, Saenen Johan B, Miljoen Hielko P, Morillo Carlos A, Divarakarmenon Syamkumar, Amit Guy, Ribas Sebastian, Baiocco Erika, Maolo Alessandro, Romandini Andrea, Maffei Simone, Connolly Stuart J, Healey Jeff S, Dokainish Hisham. Prospective Study of Tricuspid Regurgitation Associated With Permanent Leads After Cardiac Rhythm Device Implantation.. The Canadian journal of cardiology. 2018. DOI: 10.1016/j.cjca.2018.11.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.