DOI 10.1016/j.ijcard.2017.03.041
Patent haemostasis prevents radial artery occlusion in patients with an acute coronary syndrome.
Аннотация
BACKGROUND
A haemostatic technique that maintains radial artery flow ("patent haemostasis") following transradial catheterization reduces rates of radial artery occlusion (RAO) in patients with stable coronary disease. It is unclear whether this benefit extends to patients with an acute coronary syndrome (ACS).
METHODS
Patients undergoing inpatient transradial catheterization for an ACS were prospectively enrolled in a consecutive cohort study (n=300). Radial haemostasis was obtained using standard radial compression (cohort 1; n=150) or patent haemostasis (cohort 2; n=150). An end-of-case activated clotting time (ACT) was recorded and radial artery patency assessed within 24 hours of sheath removal by reverse Barbeau's test.
RESULTS
The incidence of RAO was 16.0% following standard radial compression and 5.3% following patent haemostasis (p=0.003). Univariate predictors of RAO were patent haemostasis (OR 0.30; [0.13-0.68], p=0.004), hyperlipidaemia (OR 0.46; [0.21-0.98], p=0.04), history of current smoking (OR 2.86; [1.3-6.0], p=0.015) and longer procedure times (OR 1.03/additional minute; [1.01-1.05], p=0.003). There was no association between the end-of-case ACT and RAO (OR 1.00; [0.9-1.01] p=1.00). After adjusting for covariates, patent haemostasis reduced the risk of RAO by 70% compared to standard compression (OR 0.30; [0.12-0.77], p=0.12). The c-statistic for model discrimination was 0.79 (95% CI [0.71-0.86], p<0.001). Inverse probability treatment weighted analysis also confirmed patent haemostasis as an independent predictor of reduced RAO (OR 0.38 [0.15-0.95], p=0.039).
CONCLUSION
Patent haemostasis is highly effective in preventing early RAO in patients with ACS.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.