MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/imi.0000000000000251

Медицинская библиотека · Innovations (Philadelphia, Pa.) · 2016

Axillary Artery Access for Combined Endoaortic Balloon Occlusion and Perfusion During Robotic Mitral Valve Surgery.

Ambur Vishnu V, Kadakia Sagar S, Taghavi Sharven, Jayarajan Senthil N, Kashem Mohammed Abul, McCarthy James, Shiose Akira, Wheatley Grayson H, Toyoda Yoshiya, Guy T Sloane

Клинический случайСтатьяПеревод в очереди

Аннотация

We aimed to develop a method that provides an alternative cannulation site in robotic mitral valve surgery that allows simultaneous endo-occlusion and antegrade perfusion. A 71-year-old man with severe mitral regurgitation and history of coronary artery bypass grafting underwent totally endoscopic robotic mitral valve repair. A 23-mm endoreturn cannula was placed through a 10-mm graft that was sewn to the left axillary artery. An endoballoon was passed through the Dacron/cannula complex and into the ascending aorta. This complex was used for simultaneous antegrade perfusion, endoballoon occlusion, and antegrade cardioplegia. Completion transesophageal echocardiography showed no evidence of mitral regurgitation. The patient had an uneventful postoperative course and was doing well at his 2-month follow-up appointment. The left axillary artery is a viable option for simultaneous endoballoon occlusion, antegrade perfusion, and antegrade cardioplegia in robotic mitral valve surgery. This has the potential benefit of providing antegrade perfusion, which some studies have shown to be associated with a decreased risk of complications when compared with retrograde perfusion specifically in patients with severe peripheral vascular disease.

Для цитирования: Ambur Vishnu V, Kadakia Sagar S, Taghavi Sharven, Jayarajan Senthil N, Kashem Mohammed Abul, McCarthy James, Shiose Akira, Wheatley Grayson H, Toyoda Yoshiya, Guy T Sloane. Axillary Artery Access for Combined Endoaortic Balloon Occlusion and Perfusion During Robotic Mitral Valve Surgery.. Innovations (Philadelphia, Pa.). 2016. DOI: 10.1097/imi.0000000000000251.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.