The routine use of surgical exposure approach for trans-femoral implantation of the balloon expandable aortic prosthesis is associated to a low rate of vascular complications.

DE LA Torre Hernandez José M, Moreno Raul, Lee Dae H, Garcia Del Blanco Bruno, Sanmartin Juan C, Garcia Blas Sergio, Serra Garcia Vicenç, Gaviria Koldo, Garcia Ivan, Zueco Javier

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

BACKGROUND

The most frequent complications of transfemoral aortic valve implantation are vascular (15-25%) and are related to an increase in mortality. We sought to assess the rate of vascular complications, its treatment and outcomes using a surgical approach for transfemoral implantation of Edwards-SAPIEN (Edwards Lifescience, Irvine, CA, USA) aortic valve.

METHODS

We have conducted a multicenter registry including 4 hospitals using a systematic surgical exposure approach. Vascular complications have been collected following the definitions of the Valve Academic Research Consortium.

RESULTS

From 2008 to 2013 a total of 312 consecutive patients have been included. Vascular complications were reported in 22 (7%), among those 6 (1.9%) were major whereas 16 (5.1%) were minor. Patients suffering vascular complications had significantly more previous history of peripheral vascular disease. All but one major complications occurred in women, aged 82-88 and with chronic renal failure. Hospital stay was longer in cases suffering complications (17.8±11 days vs. 9±7 days; P<0.0001). The 30 days mortality was 13.6% in patients with vascular complications, 33.3% in patients with major complications and 5.5% in patients with no complications (P=0.05).

CONCLUSIONS

In this registry, the systematic use of a surgical exposure of the femoral artery for TAVR has been associated with a lower rate of vascular complications.

Для цитирования: DE LA Torre Hernandez José M, Moreno Raul, Lee Dae H, Garcia Del Blanco Bruno, Sanmartin Juan C, Garcia Blas Sergio, Serra Garcia Vicenç, Gaviria Koldo, Garcia Ivan, Zueco Javier. The routine use of surgical exposure approach for trans-femoral implantation of the balloon expandable aortic prosthesis is associated to a low rate of vascular complications.. The Journal of cardiovascular surgery. 2015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.