Sutureless implantation of the perceval s aortic valve prosthesis through right anterior minithoracotomy.

Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Gilmanov Daniyar, Miceli Antonio, Bevilacqua Stefano, Farneti Pierandrea, Solinas Marco, Ferrarini Matteo, Glauber Mattia

Аннотация

BACKGROUND: Many new, less invasive strategies are proposed for aortic valve operation in elderly patients. Rapid deployment sutureless aortic valve prosthesis has been recently introduced. We analyzed our experience with a sutureless valve implanted through a minimally invasive approach.

METHODS: A retrospective observational study with prospectively registered data was conducted on 137 patients undergoing aortic valve replacement through a right anterior minithoracotomy. Between April 2011 and January 2013, 137 consecutive patients underwent aortic valve replacement with a recently introduced, rapid deployment, sutureless pericardial valve in minithoracotomy access (47 men; mean age, 76.6 ± 7.1 years). There were 35 obese patients with a body mass index of more than 30 kg/m(2). Mean logistic EuroSCORE I was 10.0; 74 (54%) patients were in New York Heart Association functional class III and IV. In all, 19 (13.9%), 45 (32.8%), and 73 (53.3%) patients received 21-, 23-, and 25-mm valve prostheses, respectively.

RESULTS: The mean aortic cross-clamp and cardiopulmonary bypass times were 59.3 ± 19 min and 92.3 ± 27 min, respectively. No operative mortality occurred. Median stay in the intensive care unit was 1 day, with assisted ventilation necessary for a median of 6 hours. Three cases of postoperative ischemic stroke were observed (1 patient with a previous history of an ischemic cerebral event). Median hospital length of stay was 6 days.

CONCLUSIONS: A sutureless valve for minimally invasive aortic valve replacement is a feasible, effective, and safe tool. Ultimately amplifying indications for less invasive aortic valve replacement in a high surgical risk subset of patients, it can become a valid alternative for transcatheter aortic valve implantation.