Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2012
Non-physiological increase of AV conduction time in sinus disease patients programmed in AAIR-based pacing mode.
СтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Mabo Philippe, Cebron Jean-Pierre, Solnon Aude, Tassin Aude, Graindorge Laurence, Gras Daniel
Аннотация
PURPOSE: The EVOCAV(DS) trial aimed to quantify the paradoxal atrioventricular (AV) conduction time lengthening in sinus node (SD) patients (pts) paced in AAIR-based pacing mode.
METHODS: SD pts, implanted with dual-chamber pacemaker programmed in AAIR-based pacing mode, were randomized in two arms for a 1-month period: the low atrial pacing (LAP; basic rate at 60 bpm, dual sensor with minimal slope) and the high atrial pacing (HAP; basic rate at 70 bpm, dual sensor with optimized slope, overdrive pacing) arm. At 1 month, crossover was performed for an additional 1-month period. AV conduction time, AV block occurrence and AV conduction time adaptation during exercise were ascertained from device memories at each follow-up.
RESULTS: Seventy-nine pts participated to the analysis (75 ± 8 years; 32 male; PR = 184 ± 38 ms; bundle branch block n = 12; AF history n = 36; antiarrhythmic treatment n = 53; beta-blockers n = 27; class III/Ic n = 18; both n = 8). The mean AV conduction time was significantly greater during the HAP (275 ± 51 ms) vs. LAP (263 ± 49 ms) period (p < 0.0001). Class III/Ic drugs were the only predictors of this abnormal behaviour. Degree II/III AV blocks occurred in 49 % of pts in the HAP vs. 19 % in the LAP period (p < 0.0001). Fifty-two patients (66 %) presented a lengthening of AV conduction time during exercise.
CONCLUSION: AAIR-based pacing in SD pts may induce a significant lengthening of pts' AV conduction time, including frequent abnormal adaptation of AV conduction time during exercise.
METHODS: SD pts, implanted with dual-chamber pacemaker programmed in AAIR-based pacing mode, were randomized in two arms for a 1-month period: the low atrial pacing (LAP; basic rate at 60 bpm, dual sensor with minimal slope) and the high atrial pacing (HAP; basic rate at 70 bpm, dual sensor with optimized slope, overdrive pacing) arm. At 1 month, crossover was performed for an additional 1-month period. AV conduction time, AV block occurrence and AV conduction time adaptation during exercise were ascertained from device memories at each follow-up.
RESULTS: Seventy-nine pts participated to the analysis (75 ± 8 years; 32 male; PR = 184 ± 38 ms; bundle branch block n = 12; AF history n = 36; antiarrhythmic treatment n = 53; beta-blockers n = 27; class III/Ic n = 18; both n = 8). The mean AV conduction time was significantly greater during the HAP (275 ± 51 ms) vs. LAP (263 ± 49 ms) period (p < 0.0001). Class III/Ic drugs were the only predictors of this abnormal behaviour. Degree II/III AV blocks occurred in 49 % of pts in the HAP vs. 19 % in the LAP period (p < 0.0001). Fifty-two patients (66 %) presented a lengthening of AV conduction time during exercise.
CONCLUSION: AAIR-based pacing in SD pts may induce a significant lengthening of pts' AV conduction time, including frequent abnormal adaptation of AV conduction time during exercise.